Permit Number: T03CM01853
Parcel: 110113730

Review Status: Completed

Review Details: 3RD PARTY REVIEW-COMMERCIAL TI

Permit Number - T03CM01853
Review Name: 3RD PARTY REVIEW-COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/25/2003 ELAINE ROSE ZONING REVIEW Needs Review
04/25/2003 EROSE1 NPPO REVIEW Needs Review
04/25/2003 EROSE1 FIRE REVIEW Needs Review
04/25/2003 STANTEC 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied ARCHITECTURAL:

q The construction type listed in the code review checklist on the cover of the plans (Sheet A-1) indicates "A2". Do you mean "II-A"? Please clarify. If it is "II-A" then the building is of 1-hour fire resistive construction and elements of construction need to be indicated as such.

q Please provide information on the "overall" existing building. What is the overall size of the building in square feet? What are the neighboring occupancies? Is there a need for fire barrier walls between this tenant and the neighboring tenants [2000 IBNC Sec. 302.3]? Is the existing wall to the east a rated wall? Please clarify.

q The clearance around the toilets in the restrooms is inadequate. The toilet requires a clear space 56" deep by 60" wide with no other fixture encroaching within this space [1998 ANSI A117.1 Sec. 604.3]. The lavatories are within this clearance space by about 6 inches

STRUCTURAL:

q There are no structural comments to be addressed.

MECHANICAL:

q There are no mechanical comments to be addressed.

PLUMBING:

q There are no plumbing comments to be addressed.

ELECTRICAL:

q There are no electrical comments to be addressed.
04/25/2003 EROSE1 WWM REVIEW Needs Review
04/25/2003 EROSE1 ENGINEERING REVIEW Needs Review
04/25/2003 EROSE1 WATER REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
04/25/2003 ELAINE ROSE OUT TO CUSTOMER Completed