Permit Number: T03CM01738
Parcel: 126010020

Review Status: Completed

Review Details: SITE

Permit Number - T03CM01738
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/07/2003 JIM EGAN FIRE REVIEW Approved
05/21/2003 DAVID RIVERA ZONING REVIEW Denied DSC TRANSMITTAL

FROM: David Rivera Senior Planner

FOR: Patricia Gehlen
Principal Planner

PROJECT: T03CM01738
4550 E Speedway Blvd.
Budget Car Sales - Site Plan
Transmittal date: 1st Review, May 29, 2003

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Revise the zoning classification from C-1 to C-2.

2. The parking calculations should be revised to reflect the most current criteria. Vehicle parking is based on one (1) space per 250 square feet of gross floor area and one (1) space per 10,000 square feet of gross lot area. Per the new calculation the number of required vehicle parking spaces is 30. Revise the calculation as required. Delineate and properly annotate the parking spaces that are to be used by the customers and the area reserved specifically for the vehicle display areas. The expansion of 963 is less than 25% of the existing gross floor area and the entire site does not have to meet full code compliance but all requirements for the expansion must be met. Based on the proposed building expansion, four additional vehicle-parking spaces are required and one of the spaces must be a handicap accessible space (van accessible). Show graphically on the plan the location of existing and required handicap parking spaces. The van accessible parking space must be provided with an eight (8) feet wide access aisle. Provide wheel stops where necessary for the new four required parking spaces. When revising the parking calculations include the handicap parking spaces. DS 2-02.2.1.A.8

3. The new five (5) feet wide sidewalk along the east side of the proposed addition must be physically separated from the vehicular use area (PAAL). Indicate on the plan if the sidewalk is a raised walkway or if the sidewalk will be flush with the pavement but physically separated by curbing, wheel stops, or other method. The sidewalk must also be accessible for the handicapped. Add access ramps if required to provide access to the handicap (based on the handicap vehicle parking spaces). DS 2-02.2.1.A.12

4. The previous site plan, which was submitted with the site plan submittal packet as reference is not very legible and the actual number of customer vehicle-parking spaces provided, is not clear. If the site was provided with excess vehicle parking spaces for customers and the number is greater than the number required per today's parking criteria disregard the comment regarding the wheel stops.
If you have any questions about this transmittal, please call David Rivera, (520) 791-5608.

RESUBMITTAL OF THE FOLLOWING IS REQUIRED: Revised site plan and landscape plan and requested documents.
05/30/2003 JOE LINVILLE LANDSCAPE REVIEW Denied The following items per DS 2-07.2.1 are required elements of the site plan: landscape irrigation feed point(s), landscape hardscape materials with locations, fences, walls, or vegetation for screening by type, material, height, location, and spacing. Revise the plans as necessary.

The previous plans approved for zoning compliance by the Planning Department on 10/01/84 (obtained from COT Records) include a planting plan and annotations by the reviewer which are consistent with the regulations in effect when existing development received zoning approval.
The site is still subject to this plan and will be inspected for compliance prior to occupancy. Add a note to the revised site plan referencing the requirement to comply with the provisions of the previously approved landscape plan. LUC 3.7.1.2.B.1.a,
LUC 3.7.7.4
06/02/2003 JOE LINVILLE NPPO REVIEW Approved Exc., previously developed site.
06/02/2003 PATRICIA GILBERT ENGINEERING REVIEW Denied DATE: June 2, 2003
ACTIVITY NUMBER: T03CM01738
PROJECT NAME: Budget Car Sales
PROJECT ADDRESS: 4550 E. Speedway Blvd.
PROJECT REVIEWER: James C. Tate, P.E.

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

Resubmittal Required: Site Plan, Flood Use Permit

General Comments

1. A Flood Use Permit is required.

2. Please put a note on the plan that all roof downspouts on the new addition will be routed under any adjacent sidewalk. Sidewalks must be flood free for up to the ten year event. DS 2-08.4.1.E
06/02/2003 JIM TATE SANITATION REVIEW Approved
06/04/2003 DAVID RIVERA HANDICAP-SITE REVIEW Denied See Zoning comments

Final Status

Task End Date Reviewer's Name Type of Review Description
06/04/2003 LISA LESNY OUT TO CUSTOMER Completed
06/04/2003 ANGIE SHOFFSTALL REJECT SHELF Completed