Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/ENGINE
Permit Number - T03CM01642
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/30/2003 | JOE LINVILLE | NPPO | REVIEW | Denied | Development on this property is allowed subject to the following conditions: Revise the plan as necessary to indicate compliance with the standards. 1) Compliance with DS 9-04.3.2.A&B as follows Vegetation Retention and Revegetation. A. Vegetation Retention. 1. Existing trees with four (4) inch or greater trunk diameter and cacti will be preserved in their original locations, except for building sites and access and utilities serving building sites. 2. When retention of the above trees and cacti in their original locations is not possible due to building site location, the trees and cacti will be salvaged and replanted in areas requiring revegetation, whenever possible. B. Revegetation. All cut or fill slopes which are no steeper than three horizontal to one vertical (3:1) and all utility trenches or septic leaching fields which are not located in parking or driveway areas will be revegetated in compliance with the following requirements. 1. All plants used in revegetation must be the same as the native vegetation on the site or any adjacent site prior to grading or clearing. 2. Revegetation will be accomplished with the following minimum requirements for plants. a. Desert trees, a minimum of fifteen (15) gallon size with a minimum trunk diameter of two (2) inches measured at the soil level, or large specimen cactus will be placed at the same vegetation density found on the site prior to any clearing, grubbing, or grading. b. Seeds for trees, desert shrubs, and grasses will be planted with a density adequate to control erosion and may use one of the following methods of planting or any other method approved by the Zoning Review Section at DSD. 1) Raked into the soil with appropriate mulch materials; 2) Hydroseeding; 3) Anchored mulches; or 4) Established on jute, rolled straw, or similar material. 3. A temporary watering system must be installed until the revegetation materials are established. 3.3 Slope Stabilization. All slopes steeper than a ratio of three horizontal to one vertical (3:1), with the exception of retaining walls, will be stabilized with properly engineered stone riprapping or sculptured rock as follows. A. Stone riprapping will be hand-placed on the slope. B. The stabilizing material used will blend with the natural appearance of the site or lot and the surrounding terrain. C. Vegetation retention and revegetation should be used in conjunction with riprapping. 2) The grading limits must be shown on the plans. DS 9-04.3.2 3) A revegetation plan is required. DS 9-04.3.2 4) Per condition of rezoning an inspection of disturbance limits is required prior to any grubbing or grading. Call 791-5640 Ext. 1140 prior to any disturbance. |
| 05/13/2003 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Paul Pence 1331 S. Bowline Court SUBJECT: 4130 S. Boulderfield Place Site plan T03CM01642 (First Review) T14S, R15E, Section 36 RESUBMITTAL REQUIRED: Plot plan. The Plot plan cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Show the 1' no access easement per the final plat on the West property line. See attachments. 2. See attachment for required notes on the plan. 3. Show grading limits for entire disturbance area and designate/label all other areas as Natural Undisturbed Open Space (N.U.O.S.). 4. Revise EHS per tentative plat. See attachments. 5. Add additional note. See attachment. If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate |
| 05/16/2003 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Approved | |
| 05/23/2003 | DAN CASTRO | ZONING | REVIEW | Denied | HDZ and NPPO approval required prior to Zoning Review approval of the site plan. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/27/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |
| 05/23/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |