Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM01525
Parcel: 125042120

Review Status: Completed

Review Details: RESIDENTIAL BLDG/WWM

Permit Number - T03CM01525
Review Name: RESIDENTIAL BLDG/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/05/2003 GERRY KOZIOL WWM REVIEW Approved
09/02/2003 David Witt BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM01525

9/4/03 2315 E. HAWTHORNE ST.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.



FOUNDATION PLANS:

1. PROVIDE LANDINGS AT DOORWAYS.

2. PROVIDE FOOTING FOR SPIRAL STAIRS.

3. DIMENSION THE LOCATIONS OF THE POSTS.

4. JUSTIFY THE 24" X 24" FOOTING SIZE AT MID SPAN OF THE G.L.B.



FLOOR PLANS:

1. PLEASE INDICATE THE LOCATIONS OF SAFETY GLASS. SEE R308.

2. PROVIDE A SPECIAL INSPECTOR FOR THE EPOXY. THE BLANK FORMS ARE AVAILABLE AT THE PERMIT COUNTER.

3. SHOW COMPLIANCE WITH R310 PROVIDING EGRESS FROM THE NURSERY. THE MINIMUM HEIGHT OF THE OPENING IS REQUIRED TO BE NET CLEAR 24" .

- MAXIMUM SILL HEIGHT OF 44"
- MINIMUM NET CLEAR AREA OF OPENING OF 5.0 SF.
- MINIMUM NET CLEAR DIMENSIONS OF OPENING OF 24" HEIGHT BY 20" WIDTH.







STRUCTURAL PLANS:

1. PROVIDE A LANDING AT THE TOP OF THE SPIRAL STAIRS.

2. 2 X 8's APPEAR INADEQUATE TO SPAN HALF OF THE WIDTH OF THE OVERFRAME OF THE EXISTING ROOF.

3. SPECIFY LUMBER GRADE AND SPECIES.

4. SPECIFY AND DETAIL ALL OVER FRAMING. IF SOLID SHEATHING IS USED ON THE LOWER TRUSSES, PROVIDE
MINIMUM OPENINGS OF 22" BY 30" FOR ACCESS AND VENTILATION INTO OVER FRAMED AREAS (>30 S.F.).

5. PROVIDE STAIRWAY CONNECTION DETAILS AND STRINGER SIZES. PRE-FABRICATED METAL STAIR SHALL
HAVE MANUFACTURER'S SPECIFICATIONS ATTACHED TO PLANS.

ELEVATIONS:

1. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4.

SECTIONS - DETAILS - MISC. NOTES:

1. LOCATE THESE CROSS SECTIONS ON THE PLANS. THE SECTION REFERENCES ON THE PLANS REFER TO OTHER SHEETS .

2. SEC. 3 / A-5 ; PLEASE IDENTIFY THE GABLED PORCH'S KING POST, SUPPORTING BEAM, AND THE CONNECTIVE HARDWARE. MAKE REFERENCE TO THE LOCATION OF THIS INFORMATION ON THE FRAMING PLAN.

3. PROVIDE THE POST TO BEAM AND POST TO FOUNDATION CONNECTIONS USED AT THE G.L.B.s .

4. PROVIDE CONNECTIVE HARDWARE AT THE INTERSECTION OF THE TWO G.L.B.s .

5. SEC. 2 ON A-5 ; PROVIDE A NAIL PATTERN FOR THE 2 X 6 OUTRIGGERS / T.J.I. CONNECTION .

6. ROOF FRAMING ; THE OVERHANG CAN BE AS CLOSE AS 2' FROM THE PROPERTY LINE, BUT NOT CLOSER. IF THE OVERHANG IS LESS THAN 3' FROM THE PROPERTY LINE IT IS REQUIRED TO BE 1-HR. FIRE RATED.

PLUMBING PLANS:

1. SHT. P-1 ; PLEASE SIZE THE REST OF THE DRAINS, WASTES, AND VENTS.

2. SHT. P-1 ; PROVIDE A VENT FOR THE KITCHEN SINK. IF IT'S AN AIR ADMITTANCE VALVE, PLEASE NOTE SO. IIF IT'S A CHICAGO LOOP ( A FOOT VENT ), PLEASE PROVIDE A DETAIL.

3. GAS: PROVIDE THE LENGTH OF LINE TO THE APPLIANCES, BTU DEMAND OF EACH APPLIANCE, SIZE OF
EACH BRANCH, TOTAL DEMAND & TOTAL DEVELOPED LENGTH FROM METER TO MOST REMOTE
APPLIANCE ON THE SYSTEM PER UPC 1217.2 . ¾" APPEARS INADEQUATE.

4. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE AT WATER HEATER.

MECHANICAL PLANS:

1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC ; NOT THE U.M.C.

2. PLEASE PROVIDE A RETURN AIR SIZED IN ACCORDANCE WITH M1602.2 .

3. PROVIDE COMBUSTION AIR TO THE APPLIANCES IN ACCORDANCE WITH THE STATE PLUMBING CODE.


ELECTRICAL PLANS:

1. MUCH OF THE PLAN IS TO LIGHT; PLEASE DARKEN.



2. ISLAND AND PENINSULA COUNTER TOPS SHALL HAVE AT LEAST ONE RECEPTACLE OUTLET AT EACH
COUNTER SPACE WITH A LONG DIMENSION OF 24" OR GREATER, AND A SHORT DIMENSION OF 12" OR
GREATER, PER E3801.4.2 AND E3802.4.3.

3. THE KITCHEN COUNTERTOP RECEPTACLES ARE REQUIRED TO BE SERVED BY A MINIMUM OF TWO 20 AMP CIRCUITS.

4. A RECEPTACLE IS REQUIRED TOWARD THE NORTH END OF THE COUNTER TOP NORTH OF THE REFRIGERATOR IF THERE ISN'T A PANTRY AS THE LAST CABINET……..OR SHELVES…..OR….WHAT IS IT ?

5. THE ELECTRICAL NOTES SHOULD REFER TO THE I.R.C. AND NOT THE N.E.C.

6. PLEASE NOTE THE LIGHT FIXTURES OVER THE TUB AND SHOWER ARE REQUIRED TO BE LISTED AS APPROVED FOR USE IN A WET AREA.

7. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED
OUTLET BOXES SHALL BE USED, PER E4001.6.

8. NOTE THAT LIGHT FIXTURE IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11.

9. PLEASE DIMENSION THE GROUND RODS BEING 6' MINIMUM APART.




IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
09/05/2003 CINDY AGUILAR OUT TO CUSTOMER Completed