Permit Number: T03CM01509
Parcel: 10408077C

Review Status: Completed

Review Details: SITE

Permit Number - T03CM01509
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/27/2003 JIM EGAN FIRE REVIEW Denied Fire hydrant required. Submit approved COT Water Plan. (Fire hydrant location indicated on Sht. C-3 is not acceptable.)
04/10/2003 DAN CASTRO HANDICAP-SITE REVIEW Denied Refer to Zoning Review Comment number five (5).
04/10/2003 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next
submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
(CODE SECTION/ DEVELOPMENT STANDARD)

1. Pima County Assessors records indicate the proposed site is comprised of two (2) separate lots. The lots must be combined by providing a copy of the recorded City of Tucson lot combination covenant and a copy of the approved Pima County Assessors Tax Combination form. Attached is a copy of the City of Tucson lot combination covenant. Contact the Pima County Assessors office for information regarding the Tax Combination form. (D.S. 2-02.2.1.A.2)

2. Note the correct project address on the plan. (D.S. 2-02.2.1.A.3)

3. Parking calculation for the gross lot area is incorrect. Revise the vehicle parking calculation to be based on the gross lot area, which is noted as 371,757 square feet on sheet T1. The rest of the vehicle parking required is based on one (1) space per 250 S.F. of gross floor area. Based on the "Vehicle Rental and Sales" land use class parking requirements, 117 parking spaces are required for visitors and employees. (D.S. 2-02.2.1.A.8) (D.S. 2-02.2.2.A.4)

4. The building area of the 2nd story must be included in the gross floor area, if it has not already been included. If applicable, revise all calculations as required.

5. Provide the handicap detail "COT 207" on the plan. (D.S. 2-02.2.1.A.8)

6. Revise bicycle parking calculation to be based on the total number of vehicle parking spaces provided. (D.S. 2-02.2.1.A.9)

7. If applicable, provide type, size, and height of existing and proposed free standing signage including billboards. (D.S. 2-02.2.1.A.13)

8. Label and dimension the right-of-way for Circuit Road and Auto Mall Drive. (D.S. 2-02.2.1.A.19)

9. All easements of record must be graphically shown on the plan together with recording docket and page reference, location, type, width, and purpose. (D.S. 2-02.2.1.A.20)

10. Provide proposed lighting layout and type. (D.S. 2-02.2.1.A.25)

11. Revise the development designator to "34" and add "subject to" sections 3.5.9.5.A and .B to the proposed land use noted under the development data block on sheet T1. (D.S. 2-02.2.1.A.31)

12. Revise maximum allowed F.A.R. to 2.00 under the development data block on sheet T1. (D.S. 2-02.2.2.A.3)

13. Revise the maximum allowed building height to 75 feet under the development data block on sheet T1.

14. Label and dimension the canopy, including height on the plan. (D.S. 2-02.2.1.A.6)

15. All requested changes must be made to the site and landscape plans. (D.S. 2-07.2.1.A)


If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
04/16/2003 BLANCA ESPINO SANITATION REVIEW Approved
04/16/2003 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Correct and revise project address. The permit application reads project address to be 4670 N. Circuit Rd. D.S. 2-02.2.1.A.3

2. Indicate all existing and proposed buildings and structures, including roof slope and downspouts. D.S. 2-02.2.1.A.6

3. Indicate if streets are "Public or Private". D.S. 2-02.2.1.A.18

4. Indicate dimensioned right-of-way. D.S. 2-02.2.1.A.19

5. Indicate all easements of record must be graphically shown on the plan together with recording docket and page reference. Book 40 Page 14 indicates a 5' Public Utility Easement south of the 16' Non Exclusive Access and Public Sewer and Utility Easement. Correct and revise. D.S. 2-02.2.1.A.20

6. Indicate dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. D.S. 2-02.2.1.A.21

7. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.A.23
04/18/2003 JOE LINVILLE NPPO REVIEW Approved
04/18/2003 JOE LINVILLE LANDSCAPE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/21/2003 DELMA ROBEY OUT TO CUSTOMER Completed