Permit Number: T03CM01507
Parcel: 125090630

Review Status: Completed

Review Details: 3RD PARTY REVIEW-RESIDENTIAL

Permit Number - T03CM01507
Review Name: 3RD PARTY REVIEW-RESIDENTIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/11/2003 EROSE1 WWM REVIEW Needs Review
07/11/2003 WILDAN 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied GENERAL COMMENTS:

1. This project has been reviewed for conformance with the 2000 IBC, 1997 UAC, 2000 IMC, 1998 IECC, 1999 NEC codes with local modifications, and the 1994 UPC with State of Arizona amendments. Any revisions to this plan will require an additional review and approval by Willdan.

2. Please note that per paragraph V-C of the Third Party Contract, an additional fee is charged for the third and subsequent reviews at the currently hourly rate.

ARCHITECTURAL COMMENTS:

Sheet A.4

1. The proposed roof drainage system does not provide for a secondary roof drainage method. Please review and clarify. Reference R 903.4.

STRUCTURAL COMMENTS:

Sheet S.2

1. Design Engineer shall seal structural construction drawings. Reference R301.1.2.
PLUMBING COMMENTS:

Sheet P.1

1. The proposed gas piping sizes are not in compliance. Please review and clarify the existing connected gas demand and the new gas demand for each branch line. Reference UPC 1217.


ELECTRICAL COMMENTS:

1. The service load must be broken down for each connected electric panel. Please review and clarify. Reference E3502.2 and E3604.3.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/11/2003 ELAINE ROSE OUT TO CUSTOMER Completed