Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL - SITE
Permit Number - T03CM01421
Review Name: RESUBMITTAL - SITE
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
11/19/2003 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: November 19, 2003 ACTIVITY NUMBER: T03CM01421 PROJECT NAME: Mohave Road Apartments PROJECT ADDRESS: 102 East Mohave Road PROJECT REVIEWER: Patricia Gilbert The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN AND A REVISED DRAINAGE REPORT OR AN ADDENDUM TO THE DRAINAGE REPORT. DRAINAGE REPORT 1. The vertical conversion 1.55 is incorrect which effects the WSE. The correct conversion is 2.2. Revise the WSE and the FFE in the drainage report using the correct vertical conversion from the GPS Control Point. |
12/09/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
12/10/2003 | Joseph Linville | LANDSCAPE | REVIEW | Approved | |
12/10/2003 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. A sidewalk is required adjacent to the two-way PAAL. The sidewalk must be physically separated from the vehicular travel lane by means of curbing, grade separation, barriers, railings, or other means, except at crosswalks. (D.S. 2-08.4.1) (D.S. 2-02.2.1.A.12) 2. The one-way PAAL must be a minimum of 24 feet in width due to the 90 degree parking spaces accessing the PAAL. (LUC Table 3.3.7-I) (D.S. 2-02.2.1.A.8) 3. All requested changes must be made to the site and landscape plans. (D.S. 2-07.2.1.A) 4. The resubmitted plan may be reviewed at the counter for Zoning Review compliance. Please contact me at the number below to set an appointment. If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
12/16/2003 | JOE LINVILLE | NPPO | REVIEW | Approved | SEE LANDSCAPE COMMENTS |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
12/18/2003 | DELMA ROBEY | OUT TO CUSTOMER | Completed |