Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03CM01421
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/25/2003 | JIM EGAN | FIRE | REVIEW | Denied | Approved, minum 20 feet wide, paved fire apparatus access roadway must be provided and extended to within 150 feet of all portions of exterior walls of all structures. |
| 04/03/2003 | PATRICIA GILBERT | SANITATION | REVIEW | Denied | Please refer to the Engineering comments for Solid Waste comments. |
| 04/03/2003 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: April 1, 2003 ACTIVITY NUMBER: T03CM01421 PROJECT NAME: Mohave Road Apartments PROJECT ADDRESS: 102 East Mohave Road PROJECT REVIEWER: Patricia Gilbert The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: SITE PLAN SUBMITTAL REQUIRED: FLOOD USE PERMIT APPLICATION 1. This project is in a FEMA flood hazard zone AE. A Flood Use Permit is required prior to Site Plan approval. Please see the attached Flood Use Permit Application and submit it with the next Site Plan submittal. 2. Add a note on the plan, "All roof down spouts on all structures must be routed under any adjacent sidewalk." Sidewalks must be flood free for up to the 10-yr. event. DS 2-08.4.1.E 3. Include the finish floor elevations (FFE) on the site plan. The FFE must be above the minimum recommended FFE in the Drainage Report. Please revise as necessary (see Drainage Report Comment 1 below). DRAINAGE REPORT 1. Please specify the minimum finish floor elevation (FFE) for the structures. The elevations on the Site and Grading Plans are NAVD 88. The elevations specified in the Drainage Report appear to be NGVD 29. Apply the proper conversion. The recommended elevation should be in NAVD 88. The FFE must be a minimum of one foot above the 100-yr. peak WSEL. |
| 04/14/2003 | DAN CASTRO | HANDICAP-SITE | REVIEW | Approved | |
| 04/14/2003 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. (CODE SECTION/ DEVELOPMENT STANDARD) 1. Note the building height for the office/recreation room building. Setbacks may not be verified until this information is provided. (D.S. 2-02.2.1.A.6) 2. Per LUC Table 3.3.7-I, a 24 foot wide PAAL is required. (D.S. 2-02.2.1.A.8) (D.S. 2-02.2.1.A.11) 3. Parking spaces 1-10 must be a minimum of 15.5 feet in length to allow a maximum of 2.5 feet of overhang. 4. Note the number of bedrooms proposed for each dwelling unit and revise the vehicle parking calculation to be based on the correct ratio. Refer to LUC 3.3.4 "Multi-family Dwelling 0-70 units/acre" for vehicle parking requirments. 5. If applicable, provide type, size, and height of existing and proposed free-standing signage including billboards. (D.S. 2-02.2.1.A.13) 6. Add the following note: "Multi-family dwelling is subject to LUC Section 3.5.7.1F." (D.S. 2-02.2.1.A.31) 7. All requested changes must be made to the site and landscape plans. (D.S. 2-07.2.1.A) If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608. |
| 04/17/2003 | JOE LINVILLE | NPPO | REVIEW | Denied | See redlines on sheets 2.1 & 2.2. |
| 04/17/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | See redlines on sheets 2.1 & 2.2. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/22/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |
| 04/18/2003 | MONICA VALDEZ | REJECT SHELF | Completed |