Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM01405
Parcel: 114510650

Review Status: Completed

Review Details: OTHER

Permit Number - T03CM01405
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/16/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM01405

4/17/03 9170 E. SHOWCASE LN.



PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.


SITE PLAN:

1. INDICATE THE LOCATION OF GAS, WATER, ELECTRIC AND SEWER OR SEPTIC LINE ON THE PROPERTY, AND
WHERE THEY ENTER THE BUILDING. PROVIDE THE LOCATION OF YOUR WATER METER AND SEPTIC SYSTEM
IF IT EXISTS.

2. NOTES ; THE BUILDING, MECHANICAL, AND ELECTRICAL CODES SHOULD REFER TO THE I.R.C. 2000 EDITION. THE PLUMBING CODE SHOULD REFER TO THE U.P.C. 1994 EDITION WITH STATE AMENDMENTS.

FOUNDATION PLANS:
1. 5/S2 ; THE MINIMUM FOOTING WIDTH FOR A MASONRY WALL (R403 ) IS 19" .

2. 10/S2 ; SPECIAL INSPECTION IS REQUIRED FOR THE EPOXY . SEE ALSO, 12/S3 AND 2/S2 .

3. PLEASE CLARIFY 5/S3 AND -/S3 AT THE PORCH.

4. 3/S3 ; THE 8" ANCHOR BOLT WON'T PROVIDE 7" OF PENETRATION INTO THE CONCRETE.

STRUCTURAL PLANS:

1. 2 AND 3/S3 ; ARE THE WELDING SYMBOLS IN CONFLICT WITH EACH OTHER ? ONE OR TWO SIDED WELDS ?

2. S-3 ; HAVE THE EXISTING ROOF LOADS BEEN CONSIDERED ON THE LT-2 AND LT-4 LINTELS ?

1. ROOF FRAMING PLAN ; IS 10 / S-2 AND S-3 THE DETAILS TO BE INDICATED AT THE JUNCTURE OF THE TWO WALLS ?

1. ROOF FRAMING PLAN ; DETAIL 4 / S-3 APPEARS TO CONFLICT WITH THE DESCRIPTION OF LT-3 .

5. S-3 ; PLEASE CLARIFY 5 / S-3 FOR THE BEARING DETAIL FOR LT-3 .

6. S-3 ; PLEASE SPECIFY A SERIES FOR THE 12" T.J.I.s

7. S-3 ; PLEASE CLARIFY THE INSTALLATION OF THE MC 10.4 AND THE SIZE. I CAN'T FIND IT UNDER MISCELANEOUS Cs IN THE " MANUAL OF THE STEEL CONSTRUCTION" ( GREEN STEEL BOOK ) .


8. S-3 ; THE DESCRIPTION OF LT-4 DIFFERS FROM IT'S DESCRIPTION IN NOTE 8 ON A-1

ELEVATIONS:

1. A-3 WEST ELEVATION ; CLARIFY 6 /A-3 .

SECTIONS - DETAILS - MISC. NOTES:

1.8 / A-4 ; HOW DOES THE MASONRY DOOR JAMB COMPLY WITH R606.11.2.1.13 . (REINF.)

MECHANICAL PLANS:

1. M-1 ; PROVIDE RETURN AIR. SEE R1602.3 ITEM 4 .

ELECTRICAL PLANS:

1. E-1 ; READILY ACCESSIBLE RECEPTACLES IN THE GARAGE ARE REQUIRED TO BE G.F.C.I. PROTECTED.



IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
04/17/2003 TAMI ACHONG OUT TO CUSTOMER Completed