Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T03CM01209
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/10/2003 | PAUL MACHADO | FLOODPLAIN | REVIEW | Approved | |
| 03/12/2003 | GERRY KOZIOL | WWM | REVIEW | Denied | Needs to show location of connection to public sewer. |
| 03/17/2003 | DAN CASTRO | NPPO | REVIEW | Passed | |
| 03/17/2003 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 04/07/2003 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM01209 4/7/03 3009 E. ELM ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. SITE PLAN: 1. INDICATE THE LOCATION OF GAS, WATER, ELECTRIC AND SEWER OR SEPTIC LINE ON THE PROPERTY, AND WHERE THEY ENTER THE BUILDING. PROVIDE THE LOCATION OF YOUR WATER METER AND SEPTIC SYSTEM IF IT EXISTS. FOUNDATION PLANS: 1.MR. KORY'S REPORT REQUIRES 6-#5 IN THE FOOTING FOR COLUMN 5A (SEE PG. 17) AS OPPOSED TO 4-#5's PER YOUR FOOTING #5. HAS THE STEEL IN YOUR FOOTINGS #4 AND #5 BEEN TRANSPOSED ? FLOOR PLANS: 1. COULD YOU INDICATE A HANDRAIL AND SPECIFY THE HEIGHT, IN ADDITION TO THE RAILING SPECIFIED ? 2. HOW IS LIGHT AND VENTILATION PROVIDED TO OFFICE #2 PER R303 ? 3. THE WALLS AND SOFFITS OF THE ENCLOSED SPACE UNDER STAIRS SHALL BE PROTECTED ON THE ENCLOSED SIDE WITH ½" GYPSUM BOARD PER R314.8. 4. DETAIL AND SPECIFY STAIR WIDTH (MINIMUM 36"), RISE AND RUN (MINIMUM 10" TREAD DEPTH AND 7 ¾" MAXIMUM RISER HEIGHT PER R314), LANDING WIDTH (PER R312), HANDRAIL HEIGHTS (PER R315), GUARDRAIL HEIGHT (PER R316) AND INTERMEDIATE RAIL SPACING (PER R316). 5. APPLIANCES INSTALLED IN GARAGES SHALL BE MOUNTED ON PLATFORMS AT LEAST 18" ABOVE THE FLOOR, PER M1307.3 STRUCTURAL PLANS: 1. DESCRIBE THE TJI FLOOR JOISTS AND CLARIFY THEIR CENTERS. 2. HAS THE STEEL IN THE FOOTINGS AT 5A AND 5D BEEN TRANSPOSED ? 3. RASTRA LINTEL @ COL. LINE 4 NEAR "A" ; THE ENGINEER REQUIRES 2-#5's UP AND 2-#5's DOWN. SEE PAGES #18 AND #19. 4. ON THE FLOOR FRAMING PLAN, NOTE AND DETAIL DOUBLE JOISTS PARALLEL TO BEARING PARTITIONS, DOUBLE TRIMMERS AND HEADER JOISTS AT FRAMED OPENINGS, FRAMING ANCHORS FOR TAIL JOISTS AND HEADER SUPPORT, AND BRIDGING OR BLOCKING AT THE ENDS AND BEARING POINTS OF THE FLOOR JOISTS. 5. SHOW DETAILS FOR ALL BEARING AND CRITICAL NON-BEARING CONDITIONS. 6. PROVIDE STAIRWAY CONNECTION DETAILS AND STRINGER SIZES. PRE-FABRICATED METAL STAIR SHALL HAVE MANUFACTURER'S SPECIFICATIONS ATTACHED TO PLANS. ELEVATIONS: 1. PROVIDE SECONDARY OVER FLOW FOR EACH ROOF DRAIN. 2. NOTE AND SPECIFY ALL ROOF SLOPES APPROPRIATE TO MATERIAL (SEE R905). 3. NOTE GLASS IN HAZARDOUS AREAS SHALL BE SAFETY GLASS PER R308.4. (SEE WINDOWS C AND D ) SECTIONS - DETAILS - MISC. NOTES: 1. PROVIDE SHEET 7. 2. DETAIL AND NOTE ALL I.C.F. WALL REINFORCEMENT PER R611. PLUMBING PLANS: 1. SPECIFY THE SIZE OF THE WATER SERVICE LINE. 2. PROVIDE AN ISOMETRIC DRAWING OF WASTE LINES. SHOW SIZES OF WASTE LINES, VENTS AND REQUIRED CLEANOUTS. 3. GAS: PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE, BTU DEMAND OF EACH APPLIANCE, SIZE OF EACH BRANCH, TOTAL DEMAND & TOTAL DEVELOPED LENGTH FROM METER TO MOST REMOTE APPLIANCE ON THE SYSTEM PER UPC 1217.2 4. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH 5. PROVIDE T & P LINE FOR THE WATER HEATER. 6. THE AREA OF THE VENTS THROUGH THE ROOF IS REQUIRED TO EQUAL OR EXCEED THE AREA OF THE MINIMUM REQUIRED BLDG SEWER. 7. PROVIDE "RASTRA" INFORMATION ON PLUMBING INSIDE THEIR WALL. 8. WET VENTING BETWEEN FLOORS IS NOT PERMITTED. PROVIDE AN ISOMETRIC DRAWING OF THE DWV SYSTEM. 9. PLUMBING CODE REFERENCES SHOULD BE TO THE '94 U.P.C. AS AMENDED ELECTRICAL PLANS: 1.SURFACE MOUNTED INCADESCENT LIGHTS ARE REQUIRED TO BO 12 INCHES FROM THE SHELF EDGE. SEE ELECTRICAL NOTE 2. 2. LIGHT FIXTURES LOCATED IN THE SHOWER AREA IS TO BE LISTED AS APPROVED FOR USE IN A WET AREA. SEE ELECTRICAL NOTE #4. 3. A RECEPTACLE IS REQUIRED TO BE LOCATED WITHIN 6ft. THE DOOR TO OFFICE #2. 4. THE INTERCONNECTING OF SMOKE DETECTORS IS REQUIRED. SEE ELECTRICAL NOTE #26. 5. PROVIDE AN EXTERIOR OUTLET AT GRADE LEVEL LOCATED AT BOTH THE FRONT AND BACK OF THE DWELLING, PER E3801.7. THESE OUTLETS SHALL BE GFI PROTECTED PER E3802.3. 6. PROVIDE A RECEPTACLE ON THE WALL IN THE NORTH EAST CORNER OF THE KITCHEN. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/15/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |