Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T03CM00984
Parcel: 110103060

Address:
3190 N SWAN RD

Review Status: Completed

Review Details: 3RD PARTY REVIEW-COMMERCIAL

Permit Number - T03CM00984
Review Name: 3RD PARTY REVIEW-COMMERCIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/13/2003 ELAINE ROSE ZONING REVIEW Needs Review
03/13/2003 EROSE1 WWM REVIEW Needs Review
03/13/2003 GP 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied ARCHITECTURAL COMMENTS
Sheet A1.1
1.Coordinate the callouts for partition type 7A as shown in the legend with the floor plan. Clarify if this is typical unless noted otherwise.

2.Provide the location of exits with a key plan indicating occupants direction of travel to required exits. Ref. IBC 106.1.2. Show the exit signs as required by IBC 1003.2.10 for each exit and coordinate with the electrical drawings for illumination and emergency power source.

3.Coordinate the egress illumination and emergency power provisions with the electrical drawings. Ref. IBC 1003.211.

4.The drinking fountain creates a protruding object. Specify wing walls or skirting as available from the manufacturer to comply with ANSI A117.1,307.
5.Provide landings for exterior doors numbered 159, 136 and 117. Landings must have a minimum 44" length measured in the direction of travel. Please coordinate with the structural drawings which show the information for the construction of the building foundation. Ref. IBC 1003.3.1.5.

6.Show the location of the attic access for each of the attic area spaces having a clear height greater than 30". Ref. IBC 1208.2.

Sheet A3
1.Provide the attic ventilation calculations and specify the material for compliance. Ref. IBC 1202.2.

Sheet A4
1.Reference detail 18/S3 in the wainscot detail to clarify the masonry veneer anchorage requirements. Ref. IBC 1405.

Sheet 8.1
1.In the door schedule note 1, please include the reference to Sheet SP1.


STRUCTURAL COMMENTS
General
1.Lateral design submitted indicates horizontal shear development due to wind forces at typical low roof level (13' high wall with 5' parapet) and shear load incorporated at Upper Roof 1, 2, 3 and 4 as drawn on Sheet S6 was omitted. Please clarify and update design where these wind forces will be transferred from Upper Roof Diaphragm downward. Detail on Roof Framing Plan missing straps where required at Low Roof Diaphragm discontinuity.

Sheet S1
1.Provide missing Soils Report containing foundation recommendations consistent with design criteria used for this project.

2.Clarify Special Inspections addressed on plan and erase works not applicable to this project. Please see concrete, high strength bolts, epoxy bolts.

Sheet S4
1.Coordinate uplift forces developed on page 37 of calculations for shear walls at Lines A.5 and B.5. Revise holdowns indicated at these walls to PHD8 to provide consistency with the submitted analysis.

2.Clarify where continuous foundation type F4 shall be located on plan, unable to find. Reference interior shear walls along Lines 6 and A.5 where footing width is not shown.


3.Design addressing overturning stability at foundation level is not submitted. Please recheck footings under shear walls on Lines 4 and A.5.

4.Coordinate with comment #1 on Sheet S5 and recheck two F2 spread footings below steel columns of B7 beam.

Sheet S5
1.Recheck 5-1/8 x 21 GLB - B7 beam including all applicable gravity loads from Upper Roof 4 per Sheet S6 and lower roof portion. Please note to address two concentrated reactions from Upper Roof Girder TG1, not only at one point load as used per page 12 of calculations. Verify beam adequacy and recheck total column load and foundations accordingly.

2.Reference to comment #1 above and provide additional details indicating glu-lam beam to steel column connection. See for example specific intersection of B7 with B1 beams. Also revise callout 208 and provide detail indicating cross section of glu-lam beam, upper and lower roof framing.

3.Recheck beam design along Line B. The column spacing between interior Lines 2 and 3 appears to be taken at less than the actual span. Coordinate with Architectural dimensions and include appropriate revision in footing design mentioned in comment #1 above.

Sheet S6
1.Clarify and callout for mechanical connector between TG2 to TG1 truss at Upper Roof 4 Framing Plan.


PLUMBING COMMENTS
Sheet P1
1.Replace Keynote 6 indicating 1-1/2" vent for water closet in toilet 148.

2.Indicate cleanouts for P3 in Conference 127 and P4 in Nurse Station adjacent to P11. UPC 707.4.

Sheet P2
1.Revise plumbing fixture schedule to comply with UPC Tables 6-3 and 7-3 as follows:
a.Apply four water fixture units for Shower Trim
b.Revise total waste fixture units for water closet to reflect 36 fixture units
c.Apply 5 fixture units for hose bibb.
d.Apply 10 water fixture units for P9.
e.Revise drainage fixture units for P3, P4, P5 and P10 to reflect three units each.
f.Adjust totals and consider impact on sizing calculations.

2.Coordinate with energy comments to provide heat traps in Water Heater Detail if compliance through only Chapter 7 is demonstrated. IECC Section 707.4.
3.Coordinate with architectural to provide complete roof drainage systems in accordance with UPC Appendix D, 3"/hr.

Sheet P3
1.Indicate cleanout for lower P3 in detail 7/P3. UPC 707.4.


CIVIL PLANS
Public Sewer Improvement Plans
Sheet 1 of 5
1.One additional sewer connection (four total) is indicated at North side of building than is shown on Sheet P1 (three total). Please coordinate.

Water Plans
Sheet 2 of 3
1.Water supply connection indicated at North side of building (three total) is not shown on Sheet P1 (two total). Please coordinate.

2.Provide locations of RPBP immediately after meters.


MECHANICAL COMMENTS
General
1.Energy calculations submitted indicate compliance with envelope requirements per IECC Section 702. Heat pump SEER ratings reflect compliance with Section 703. Provide documentation of compliance for Sections 704 and 705 or provide compliance by provisions of ASHRA/IES Energy Code for Commercial and High Rise Residential Buildings. IECC 701.2.

2.Coordinate with Architectural to provide details of rooftop access for service of units. IMC 306.5.

Sheet M1
1.Revise Mechanical General Note 10 to indicate required duct detectors shall be in return air duct upstream of filters and outside air connections. IMC 606.2.1.

2.Provide minimum 100 sq in of make-up air to laundry closet. IMC 504.5.

3.Provide dryer vent and cleanout. IMC 504.3 and 504.6.1.

4.Indicate heat pumps will be permanently identified as to the area served. IMC 304.10



ELECTRICAL COMMENTS
General
1.Please identify all patient care areas (see Sheet A1.1). Ref. NEC 517.13(a) and (b) as noted under Note #2.

2.Review all receptacles in patient care areas for GFI protection. Ref. NEC210-8 (a) (7) by city of Tucson as amended.
03/13/2003 EROSE1 WATER REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
03/13/2003 ELAINE ROSE OUT TO CUSTOMER Completed