Permit Number: T03CM00919
Parcel: 133170630

Address:
350 N WILMOT RD

Review Status: Completed

Review Details: SITE

Permit Number - T03CM00919
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/28/2003 JIM EGAN FIRE REVIEW Approved
03/06/2003 DAN CASTRO HANDICAP-SITE REVIEW Passed
03/06/2003 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. The following comments area based on a less than 25% building area expansion requiring full code compliance review of the expansion only. Since the expansion is less than 25%, a copy of the last approved site plan must be provided for reference.

2. Note the legal description of the property.
D.S. 2-02.2.1.A.2

3. Add the location map.
D.S. 2-02.2.1.A.4

4. Add a small index drawing of the site showing the proposed addition. The index drawing must show all property lines and dimensions.
D.S. 2-02.2.1.A.5

5. Note the proposed building height of the addition.
D.S. 2-02.2.1.A.6

6. Per D.S. 3-05.2.2.B.1, a minimum setback of five (5) feet for a pedestrian refuge area must be maintained between any enclosed structure and a PAAL.
D.S. 2-02.2.1.A.12

7. Add the following general note: "No additional loading zone spaces required for this expansion."
D.S. 2-02.2.1.A.14/ D.S. 2-02.2.2.A.5

8. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference.
D.S. 2-02.2.1.A.20
03/11/2003 ANY SANITATION REVIEW Approved To: Cdg Architects
Frank Mascia
2102 N. Country Club Road, Ste. #9
Tucson, Arizona 85716

SUBJECT: 350 N. Wilmot Road
Site plan T03CM00919 (First Review)
T14S, R15E, Section 07

RESUBMITTAL REQUIRED: None.

Site Plan:

The site plan is approved by engineering/floodplain.


If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate,
03/11/2003 PAUL MACHADO ENGINEERING REVIEW Approved To: Cdg Architects
Frank Mascia
2102 N. Country Club Road, Ste. #9
Tucson, Arizona 85716

SUBJECT: 350 N. Wilmot Road
Site plan T03CM00919 (First Review)
T14S, R15E, Section 07

RESUBMITTAL REQUIRED: None.

Site Plan:

The site plan is approved by engineering/floodplain.


If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate,
03/11/2003 ANY FLOODPLAIN REVIEW Approved To: Cdg Architects
Frank Mascia
2102 N. Country Club Road, Ste. #9
Tucson, Arizona 85716

SUBJECT: 350 N. Wilmot Road
Site plan T03CM00919 (First Review)
T14S, R15E, Section 07

RESUBMITTAL REQUIRED: None.

Site Plan:

The site plan is approved by engineering/floodplain.


If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate,
03/20/2003 JOE LINVILLE LANDSCAPE REVIEW Passed
03/20/2003 JOE LINVILLE NPPO REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
03/21/2003 LISA LESNY OUT TO CUSTOMER Completed