Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T03CM00789
Review Name: RESUBMITTAL
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
01/05/2004 | Martin Haeberle | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Footprint on site plan differs from the architectural floor plan. Revise plan. Note: Revise all sheets. See roofing plan, mechanical, etc… 2. Clarify property line location in relation to addition. Fire separation and protection of openings required at property line. Revise plans. Note: Although encroachment has been moved footings still encroach into common area. 3. Opening for the guardrail may not allow a sphere of 4" to penetrate it. Revise plans. Plans still reflect greater openings 4. Provide smoke detector at top of stairs. Not shown on electrical sheet Electrical 1. Indicate size and type of feeder to be used for subpanel. Still not specified on plans. Per Robert Sherry, Mechanical / Plumbing Plans Examiner Mechanical Comments: The submitted “MEC calculations using %” is not acceptable under the current code; refer to Chapter 11, IRC 2000, Sections N1101.2.2, N1103, and N1104. Show the wall insulation requirements on the drawings. Show the U-values of the specified windows on the drawings. Provide information to show that the exhaust fan for first floor bathroom is in compliance with Section R303.1, IRC 2000. Plumbing Comments: Show the complete plumbing plan, including waste and vent isometrics on the drawings. Coordinate the waste piping shown on the floor plans with the riser diagrams. Reference Section 302.3, Uniform Administrative Code 1997. Based on the submitted calculations, a 1-1/2” pipe is not capable of supporting greater than 64 fixture units (Table 6-4, 45-60 PSI, 200 feet). Show the calculations on the drawings. Reference Section 610.4, UPC 1994. Show all fixture descriptions (including sinks, bathtub and shower) on the drawings. Reference Section 302.3, Uniform Administrative Code 1997. Show drainage piping calculations on plans in accordance with Sections 702.0 and 703.0, UPC 1994 with AZ State amendments. Provide upper terminal cleanouts for new plumbing fixtures. Reference Section 707.4, UPC 1994 as amended by the State of Arizona. Clarify the drain from the clotheswasher; it appears to be wet vented into the water closet vent. Reference Section 908.1, UPC 1994. |
12/11/2003 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
01/06/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |
01/06/2004 | ANGIE SHOFFSTALL | OUT TO CUSTOMER | Completed |