Review Date Reviewer's Name Type of Review Description Status Comments
02/12/2003 JIM EGAN FIRE REVIEW Approved 1. FIRE HYDRANTS REQUIRED. SUBMIT APPROVED COT WATER PLAN.
2. "HEAVY EQUIPMENT " BUILDING IS NOT B-OCCUPANCY. S-2 REPAIR GARAGE IS MORE APPROPRIATE. SEE 2000 IBC SEC. 406.6.2 FOR MIXED OCCUPANCY SEPARATIONS RELATED TO REPAIR GARAGES.
3. "HEAVY EQUIPMENT" AND "WAREHOUSE" BUILDINGS DO NOT HAVE ADEQUATE EXTERIOR OPENINGS TO COMPLY WITH 2000 IBC SEC. 902.2.12.1. FIRE SPRINKLERS ARE REQUIRED OR ADDITONAL OPENINGS MUST BE PROVIDED.
03/03/2003 DAN CASTRO ZONING REVIEW Z_DO NOT USE
03/03/2003 DOUG WILLIAMS FLOODPLAIN REVIEW Z_DO NOT USE
03/03/2003 MARTIN HAEBERLE BUILDING-COMMERCIAL REVIEW Z_DO NOT USE