Permit Number: T03CM00747
Parcel: 111060540

Review Status: Completed

Review Details: SITE

Permit Number - T03CM00747
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/19/2003 JIM EGAN FIRE REVIEW Approv-Cond FIRE SPRINKLERS PROVIDED FOR UNITS 6 THROUGH 11 IN LIEU OF FIRE APPARATUS ACCESS.
03/04/2003 JOE LINVILLE NPPO REVIEW Approved
03/04/2003 JOE LINVILLE LANDSCAPE REVIEW Approved
03/17/2003 BLANCA ESPINO FLOODPLAIN REVIEW Denied SEE ENGINEERING COMMENTS.
03/17/2003 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Indicate lot bearings along with lot dimensions. D.S. 2-02.2.1.A.5

2. Indicate all existing and proposed buildings and structures roof slopes and downspouts. D.S. 2-02.2.1.A.6

3. Indicate drainage patterns, proposed finish floor elevation(s) and finish grades. D.S. 2-02.2.1.A.16

4. Correct and revise estimated cut and fill quantities on Site Plan and Grading Plan to match. A Grading Plan Review is required. Submit an approved Site Plan along with Grading Plan. D.S. 2-02.2.1.A.17

5. Indicate if street is Public or Private. D.S. 2-02.2.1.A.18

6. Indicate a dimension of right-of-way. D.S. 2-02.2.1.A.19

7. Indicate dimension from street monument lines to existing and proposed utility lines. D.S. 2-02.2.1.A.21

8. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.A.23
03/17/2003 BLANCA ESPINO SANITATION REVIEW Approved
03/19/2003 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. The legal description on sheet C1 indicates a different address than what is noted in the title block. Please revise for consistency.
D.S. 2-02.1.1.A.2/ D.S. 2-02.2.1.A.3

2. If applicable, provide a detail of existing and/or proposed free standing signage on the site plan.
D.S. 2-02.2.2.1.A.13

3. Label and dimension existing half right-of-way for Blacklidge Drive.
D.S. 2-02.2.1.A.19

4. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference.
D.S. 2-02.2.1.A.20

5. Under the proposed use noted on sheet C1, please add the applicable "subject to: Sec. 3.5.7.1.F."
D.S. 2-02.2.1.A.31

6. All requested changes must be made to the site and landscape plans.
D.S. 2-07.2.1.A

7. Review of this plan by the Zoning Review Section may be done over the counter. Please contact Dan Castro to set an appointment.
03/19/2003 DAN CASTRO HANDICAP-SITE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
04/14/2003 TAMI ACHONG OUT TO CUSTOMER Completed