Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW-COMMERCIAL
Permit Number - T03CM00733
Review Name: 3RD PARTY REVIEW-COMMERCIAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/26/2003 | EROSE1 | WWM | REVIEW | Needs Review | |
| 08/26/2003 | GP | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Denied | ARCHITECTURAL COMMENTS Sheet 1 1. Exterior walls and openings are less than 3 feet from the property line. Walls are required to have a 1-hour fire rating both sides and openings are not permitted. Refs. R302.1, R302.2. Sheet 2 1. Clarify foundation width in detail 2/2. Sheet 3 1. A-C wall type does not appear to have been used. Please clarify. 2. Notes reference a footing schedule. No footing schedule was provided. Please clarify. Sheet 6 1. Mid-height blocking is called out at 8'0" maximum in the typical framing detail. Please revise. STRUCTURAL COMMENTS General 1. Provide the lateral analysis and calculations prepared by an Arizona P.E. 2. Provide the engineered truss design prepared by an Arizona P.E. PLUMBING COMMENTS Sheet 9 1. Revise gas pipe sizing to comply with UPC 1217. 2. Complete the waste line sizes. Ref. UPC Table 7-5. 3. Show the required cleanouts. Ref. UPC 707.4. MECHANICAL COMMENTS Sheet 8 1. Coordinate mechanical equipment specifications with the electrical plan. ELECTRICAL COMMENTS Sheet 7 1. Note countertop receptacles as ground fault circuit interrupter protected. Ref. E3802.6. 2. Note garage receptacles as ground fault circuit interrupter protected. Ref. E3802.2. 3. Show disconnect and WP GFI receptacle for rooftop mechanical equipment. 4. Show the oven and range as circuits 2 and 4 as indicated in the panel schedule. 5. Show the location of the heat pump. Coordinate with mechanical. 6. Relocate the convenience receptacles in the study to comply with E3801.2. 7. Circuit 22 does not appear to have been used. Please show as a spare in the panel schedule. ENERGY COMMENTS - The energy portion has been reviewed and approved. |
| 08/26/2003 | EROSE1 | WATER | REVIEW | Needs Review | |
| 08/26/2003 | EROSE1 | FIRE | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 08/26/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |