Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T03CM00693
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
02/25/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
02/25/2003 | GERRY KOZIOL | WWM | REVIEW | Passed | no fixtures added |
02/25/2003 | MARTIN HAEBERLE | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Provide structural analysis of proposed ramp. Note: utilize a minimum of 100 pounds per square foot live load. Reference Table 1607.1 IBC 2. Occupant load for assembly area to be calculated at 7 net not 15. Revise plans. 3. The proposed addition causes the school to be below the minimum number of fixtures required. Revise plans to reflect compliance with Table 2902.1 IBC 4. Provide location and detail for required 1-hour fire barrier for storage areas per Table 302.1.1 IBC. 5. Electrical panel and fire extinguisher cabinet is located within fire barrier walls. Indicate how one- hour firewall integrity is to be maintained. 6. Revise door schedule to reflect required fire rated door assemblies. 7. Provide accessible means of egress required from assembly spaces per section 1003.2.13 IBC. 8. Provide an exit travel plan for the assembly areas. 9. Encroachment into the exit travel by door # 205 is not allowed per section 1003.2.3.1 IBC |
02/25/2003 | PATRICIA GEHLEN | ZONING | REVIEW | Passed | |
02/27/2003 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
03/03/2003 | ROBERT SHERRY | WATER | REVIEW | Approved | |
03/03/2003 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Provide calculations for sizing of the new natural gas piping. Reference Section 1217.3, UPC. 2. Indicate minimum slope of horizontal rainwater and overflow piping on plans. Reference Appendix D3.3, UPC. |
03/03/2003 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide signature of Principal Envelope Designer on the International Energy Code Compliance form. 2. Indicate location of duct smoke detectors on plans. Reference Section 606.2, IMC. 3. Provide ventilation calculations. Reference Section 403.2, IMC. |
03/10/2003 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/17/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |