Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T03CM00684
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/07/2003 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 02/07/2003 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 02/07/2003 | ANY | FLOODPLAIN | REVIEW | Approved | |
| 02/14/2003 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 03/10/2003 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM00684 3/10/03 1111 E. HEDRICK ST. #1 & #2 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FLOOR PLANS: 1. THE AREA OF THE OPENING BETWEEN THE INTERIOR BEDROOM AND THE BONUS ROOM IS REQUIRED TO BE 50% OF THE AREA OF THE COMMON WALL. PLEASE SPECIFY THIS OPENING. 2. SHOW COMPLIANCE WITH R303.1 PROVIDING NATURAL LIGHT INTO ROOMS (8%). 3. SHOW COMPLIANCE WITH R303.1 PROVIDING NATURAL VENTILATION (4%). 4. SHOW COMPLIANCE WITH R310 PROVIDING EGRESS FROM BEDROOMS. (SEE ALSO R303.2 ) - MAXIMUM SILL HEIGHT OF 44" - MINIMUM NET CLEAR AREA OF OPENING OF 5.7SF. - MINIMUM NET CLEAR DIMENSIONS OF OPENING OF 24" HEIGHT BY 20" WIDTH. PLUMBING PLANS: 1. WATER LINE: PROVIDE TOTAL FIXTURE DEMAND & MAXIMUM DEVELOPED LENGTH. PLEASE JUSTIFY THE EXISTING WATER SERVICE LINE FROM THE WATER METER TO THE "T" TO THE NEW RISIDENCE. (INCLUDE HOSE BIBS AND USE THE '94 U.P.C.) 2. NOTE ON PLAN COMPLIANCE WITH WATER CONSERVATION; WATER CLOSETS 1.6 GALLONS PER FLUSH, SINKS AND SHOWERHEADS 3 GALLONS PER MINUTE. 3. THE PLUMBING AND GAS NOTES SHOULD REFER TO THE '94 U.P.C. AS AMENDED BY THE STATE. THE CITY OF TUCSON HAS NOT ADOPTED THE PLUMBING PORTION OF THE I.R.C. MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC, NOT THE U.M.C. AS NOTED IN MECHANICAL NOTE #8 ON MPE.2 . ELECTRICAL PLANS: 1. THE RECEPTACALS IN THE BONUS ROOM APPEAR TO BE OVER SPACED. 2. ON WHICH CIRCUIT IS THE KITCHEN RECEPTACAL LOCATED SOUTH OF THE RANGE ? 3. THE ELECTRICAL NOTE #1 SHOULD REFER TO THE CITY OF TUCSON. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/10/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |