Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM00678
Parcel: 112073940

Address:
2810 E COPPER ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T03CM00678
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/06/2003 GERRY KOZIOL WWM REVIEW Approved
03/28/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM00678

3/28/03 2810 E. COPPER



PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.


STRUCTURAL PLANS:

1. S-4/C , PLEASE JUSTIFY THE LAGS IN THIS DETAIL. I HAVEN'T FOUND THE "HANDOUT" TO WHICH YOU REFERRED.

2. DTL. 3 ON S-3 , PROVIDE VENTILATION FOR THE RAFTER SPACE OR PROVIDE "FULL-THICK" INSULATION. SEE ALSO S4/A .

PLUMBING PLANS:

1. GAS, PLUMBING, AND COMBUSTION AIR IS TO BE IN ACCORD WITH THE STATE PLUMBING CODE ( '94 U.P.C. AS AMMENDED ).THE AMENDMENTS ARE AVAILABLE FROM THE CITY CLERK FOR A HARD COPY, OR ON LINE AT WWW.CI.TUCSON.AZ.US

2. COMBUSTION AIR APPEARS TO BE IN CONFLICT WITH THE STATE PLUMBING CODE.

ELECTRICAL PLANS:

1. THE LIGHT OVER THE TUB IS TO BE LISTED AS APPROVED FOR USE IN A WET AREA. FIXTURES LISTED FOR USE IN A WET AREA CAN BE USED IN BOTH WET AND DAMP AREAS. FIXTURES LISTED FOR USE IN DAMP AREAS CAN BE USED IN DAMP AREAS BUT NOT WET AREAS. THESE ARE TWO DIFFERENT FIXTURES. SEE R3401 OR N.E.C. ART. 100 UNDER "LOCATION".

2. THE EXISTING DWELLING IS REQUIRED TO BE PROVIDED WITH SMOKE DETECTORS. SEE R317.1.1 . NOTE E-6 SAYS "AUDIBLE" IN ALL SLEEPING AREAS WHILE THE CODE SAYS "PROVIDED WITH".

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
03/31/2003 DELMA ROBEY OUT TO CUSTOMER Completed