Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T03CM00678
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/19/2003 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T03CM00678 2810 E. COPPER ST. 2/21/03 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. S1/A ; THE ANCHOR BOLT IS REQUIRED TO BE EMBEDDED 7" INTO THE 10" BLOCK. SEE FIGURE R403.1(1) . 2. S1/A ; PLEASE SPECIFY THE MUD SILL ANCHOR STRAPS AND THEIR O.C. SPACING. 3. ALTERNATE MONOPOUR FOUNDATION FOOTING/STEM….. ; PROVIDE WEATHER PROTECTION OVER THE O.S.B. 4. VENEER ; PROVIDE FLASHING AND WEEP HOLES. SEE R703.7.5 & R703.7.6 . 5. S1/B ; PLEASE SPECIFY THE PLATE/CONCRETE CONNECTION . FLOOR PLANS: 1. PLEASE DIMENSION THE MINIMUM HALLWAY WIDTH . 2. SHT. S-2, BRACED WALL PANEL NOTE "HD1" ; PLEASE PROVIDE BROCHURE TO VERIFY TENSILE STRENGTH OF "HDC5/22-SDS3" 3. SHT. 2 ; "HD2A" REQUIRES 2 STUDS. 4. SHT. 2 ; "STHD 10" REQUIRES 28 - 16d SINKERS . 5. SHT. 2, LINTEL SCHEDULE ; BRICK VENEER REQUIRES A SINGLE ANGLE IRON LINTEL. 6. SHT. 2 ; PLEASE PROVIDE A HEADER OVER THE HALLWAY . STRUCTURAL PLANS: 1. SHT. S-3 , STRUCTURAL SHEATHING &NAILING…… , 6d NAILS ARE INADEQUATE FOR ¾ " SUB-FLOOR. SEE TABLE R602.3(1) . 2. S-4/C ; JUSTIFY THE LAGS IN THIS DETAIL. 3. SPECIFY LUMBER GRADE AND SPECIES. ARE THE ROUND POSTS ALSO D.F. #2 ? 4. DTL. 3 ON S-3 AND S4/A ; IN THE ABSENCE OF VENTILATION, THE INSULATION IS REQUIRED TO BE FULL THICK. 5. S4/A ; HOW WILL THE VENTED FRIEZE BOARDS VENT WITH SOLID SOFFIT ? PLUMBING PLANS: 1. ALL GAS, PLUMBING, AND COMBUSTION AIR IS TO BE IN ACCORD WITH THE STATE PLUMBING CODE ('94 U.P.C. WITH SOME STATE AMMENDMENTS). 2. PROVIDE PRESSURE AND TEMPERATURE RELIEF VALVE AT WATER HEATER. 3. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. MECHANICAL PLANS: 1. PROVIDE COMBUSTION & RELIEF AIR FOR THE WATER HEATER. ELECTRICAL PLANS: 1. RECEPTACLES OVER THE TUB ARE NOT PERMITTED. SEE R3902.10 . 2. LIGHT FIXTURES OVER THE TUB ARE TO BE LISTED FOR USE IN A WET AREA;NOT A DAMP AREA. FIXTURES APPROVED FOR WET AREAS ARE ACCEPTABLE IN DAMP AREAS, BUT FIXTURES APPROVED FOR DAMP AREAS AREN'T APPROVED FOR WET AREAS. 3. THE CLOTHES WASHER IS REQUIRED TO BE ON A 20 AMP CIRCUIT. 4. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. 5. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11. 6. PLEASE NOTE THE EXISTING DWELLING IS REQUIRED TO BE EQUIPPED WITH SMOKE DETECTORS. SEE R317.1.1 . MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL MODEL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES. |
| 02/25/2003 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/28/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |