Permit Number: T03CM00567
Parcel: 130070070

Review Status: Completed

Review Details: SITE

Permit Number - T03CM00567
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/10/2003 JIM EGAN FIRE REVIEW Approved
06/24/2003 DOUG WILLIAMS ENGINEERING REVIEW Denied SUBJECT: Eric's Automotive
REVIEWER: Doug Williams
DATE: 24 June 2003
ACTIVITY NUMBERS: T03CM00567
T14S, R14E, Sec. 21


SUMMARY: Engineering Division has reviewed the Site Plan received on 24 June 2003. Please address the following comment:

1. The Alvernon Way right-of-way depicted does not appear to correspond with current records. As depicted, parking spaces for the business are within a portion of the right-of-way, and require a Temporary Revocable Easement (TRE) to be obtained prior to Engineering Division approval of the Site Plan. Contact Tucson Department of Transportation (TDOT)-Real Estate Division at 791-5100 for current right-of-way or TRE related inquiries.

Please provide a revised site plan or a copy of the TRE addressing the above comment. For questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us.

Douglas Williams
Sr. Engineering Associate
Engineering Division
Development Services Department
06/27/2003 DOUG WILLIAMS SANITATION REVIEW Passed
07/07/2003 JOE LINVILLE LANDSCAPE REVIEW Approved No landscape plans req.
07/07/2003 JOE LINVILLE NPPO REVIEW Approved Full y developed site w/ no PP's., exception.
07/08/2003 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next
Submittal, which states how all Zoning Review Section comments Regarding the Land Use Code and Development Standards were Addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Note the proposed height for the canopy. (D.S. 2-02.2.1.A.6)

2. Dimension the width and length of the new vehicle parking spaces and wheelstop location. Wheelstop must be located two and one-half (2½) feet from the front of the parking space per D.S. 3-05.2.3C.2
(D.S. 2-02.2.1.A.8)

3. Where is parking space 14? If applicable, revise numbering of spaces.

4. Note the number of vehicle parking spaces existing and proposed. (D.S. 2-02.2.2.A.4)

5. The future right-of-way dimension is not located in the same location as on the last approved site plan. Please clarify correct right-of-way.

6. Canopy setback from Alvernon Road and Juarez Street may not be verified for compliance until the canopy height has been provided. Per LUC Sec. 3.2.6.5.B.1, the canopy setback from Alvernon Road is based on the greater of 21 feet or height of structure measured from the back of future curb. Minimum setback required for Juarez Street is based on the greater of 21 feet or the height of the canopy measured from the outside edge of the nearest adjacent travel lane. Label and dimension the aforementioned setbacks from the required locations.

7. Per ICC/ANSI A117.1-1998 Section 502.3.1, the minimum width for a van accessible access aisle is eight (8) feet. The plan shows a seven (7) foot width.

8. Clarify whether the sign north of parking space 15 is new or existing . The last approved site plan also indicates this sign as being new. If new provide a fully dimensioned detail for the sign.

9. Remove reference to "new office addition" if the note was left over from the last approved site plan. If a new addition to the office is proposed provide all applicable information and calculations.


If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
07/10/2003 DAVID RIVERA HANDICAP-SITE REVIEW Denied Per ICC/ANSI A117.1-1998 Section 502.3.1, the minimum width for a van accessible access aisle is eight (8) feet. The plan shows a seven (7) foot width.

Final Status

Task End Date Reviewer's Name Type of Review Description
07/17/2003 SUE REEVES OUT TO CUSTOMER Completed
07/10/2003 ANGIE SHOFFSTALL APPROVAL SHELF Completed