Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T03CM00499
Parcel: 10824012A

Address:
2480 E RIVER RD

Review Status: Completed

Review Details: 3RD PARTY REVIEW-COMMERCIAL

Permit Number - T03CM00499
Review Name: 3RD PARTY REVIEW-COMMERCIAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/21/2003 JIM EGAN FIRE REVIEW Approved
03/24/2003 GP 3RD PARTY REVIEW-COMMERCIAL REVIEW Approved
03/27/2003 ROBERT SHERRY WATER REVIEW Approved
03/27/2003 GERRY KOZIOL WWM REVIEW Denied Needs to build public sewer.
03/28/2003 CRAIG GROSS ZONING REVIEW Approved
04/04/2003 BLANCA ESPINO FLOODPLAIN REVIEW Denied Site Plan
1. Demonstrate erosion prevention technique for splash block and it's surrounding areas. D.S. 2-02.2.1.A.6

2. Indicate drainage patterns and finish grades. D.S. 2-02.2.1.A.16

3. Indicate estimated cut and fill quantities. A Grading plan review may be required. No grading can occur until 30 days prior to construction. Construction plans must be in review process for permits, or construction permits must have already been issued. Grading permits are to cover only those areas for which building permits are granted as per Development Plan D01-0038, General Notes #29. D.S. 2-02.2.1.A.17

4. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.A.23

5. Indicate refuse container location and access thereto fully dimensioned. D.S. 2-02.2.1.A.32

6. A Floodplain Use Permit and an Elevation Certificate are required as per DP D01-0038, General Notes #25.

Drainage Statement
1. A Drainage Statement is required to identify drainage issues for Lot 13.

Final Status

Task End Date Reviewer's Name Type of Review Description
04/08/2003 TAMI ACHONG OUT TO CUSTOMER Completed