Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T03CM00366
Parcel: 123111210

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/ENGINE/WWM

Permit Number - T03CM00366
Review Name: RESIDENTIAL BLDG/ZONING/ENGINE/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/16/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM00366


4/16/03 1415 E. LESTER #2


PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ΒΌ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.



STRUCTURAL PLANS:

1. HEADER SCHEDULE DOESN'T WORK IN ALL CASES. THE HEADERS ARE SPECIFIED ON THE FRAMING PLAN AND THEY WORK. IF YOU'RE CHANGING OR ADDING OPENINGS, SUBMIT "AS-BUILT" DRAWINGS. PLEASE DELETE THE HEADER SCHEDULE IF YOU'RE NOT GOING TO USE IT.

2. FRAMING NOTE #10, THE Fb ARE NOT CURRENT. #2 D.F. IS 875 p.s.i. and #1 d.f. is 1000 p.s.i. .

SECTIONS - DETAILS - MISC. NOTES:

1. DETAIL 1 ON 2 ; PROVIDE FIRE BLOCKS.

2. DETAIL 5 ON 3 ; PROVIDE PLATE TO FLOOR CONNECTION.

PLUMBING PLANS:

1. PLEASE ELIMINATE THE "S-TRAPS" AT THE UPSTAIRS AND DOWNSTAIRS BATH TUBS. ( SEE THE PLUMBING ISOMETRIC )

MECHANICAL PLANS:

1. IF YOU LEAVE THE COMBUSTION AIR NOTES FOR THIS ALL ELECTRIC HOUSE, PLEASE CHANGE IT TO BE IN CONFORMANCE WITH THE '94 U.P.C. AS ADOPTED BY THE C.O.T.

2. PLEASE SPECIFY THE MECHANICAL EQUIPMENT AND CORRECT THE R/A SIZING IN NOTE 4 OF THE MECHANICAL NOTES.


ELECTRICAL PLANS:

1. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED
OUTLET BOXES SHALL BE USED, PER E4001.6.

2. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11.

3. SHOW LOCATIONS OF SMOKE DETECTORS PER R317. NOTE THAT ALL SMOKE DETECTORS MUST BE
INTERCONNECTED WITH A POWER SOURCE FROM THE BUILDING WIRING, AND SHALL BE EQUIPPED WITH
BATTERY BACKUP.



IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110
04/17/2003 GERRY KOZIOL WWM REVIEW Needs Review

Final Status

Task End Date Reviewer's Name Type of Review Description
04/17/2003 TAMI ACHONG OUT TO CUSTOMER Completed