Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T03CM00361
Parcel: 12703448D

Address:
801 N SAHUARA AV

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T03CM00361
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/14/2003 GERRY KOZIOL WWM REVIEW Approved
02/26/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T02CM00361


2/28/03 801 N. SAHUARA AVE.


PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

FLOOR PLANS:

1. SAFETY GLAZING IS REQUIRED FOR THE 4060 XO . SEE R308.4 , ITEM #9.

2. PLEASE CONFIRM THE Fb VALUES CITED IN FLOOR PLAN NOTE #1 AND SPECIFY THE GRADES.

3. PROVIDE "SEPARATION" FOR THE GARAGE AS SPECIFIED IN R309.2 .

12. DETAIL AND SPECIFY STAIR WIDTH (MINIMUM 36") AND HANDRAIL HEIGHT (PER R315).

STRUCTURAL PLANS:

1. THE BEARING WALL BETWEEN THR GARAGE AND THE STAIRWAY IS REQUIRED TO HAVE A 19" (MIN.) FOOTING WIDTH. SEE TABLE R403.1 .

2. IS A FOOTING EXISTING UNDER THE NORTH WALL OF THE CARPORT ? THIS WILL BE A REQUIRED BRACED WALL (SHEAR WALL) AND REQUIRES A 19" FOOTING .

3. FLOOR FRAME , PLEASE JUSTIFY THE 5 1/8 X 12 GLU-LAM SUPPORTING THE ROOF AND THE FLOOR OVER THE GARAGE DOOR .

SECTIONS - DETAILS - MISC. NOTES:

1. PLEASE PROVIDE CONNECTIONS FOR THE TOP AND BOTTOM OF THE STAIRS .

2. C/5 ; THE LEDGER/STUD CONNECTION IS REQUIRED TO HAVE 5 - 16d NAILS WITH THE A-35.

3. PROVIDE A BOX BEAM DETAIL. BLOCKING , FILLERS , CONNECTIONS ,….

4. NOTE AND SPECIFY THE LENGTH OF ANCHOR BOLTS FOR SILL PLATES.

5. F/5 ; PROVIDE A #4 VERT. @ EACH CORNER OF THE MASONRY COLUMNS. SEE R606.11.2.2.3 .

6. STAIR DETAIL ; THE WALL ABOVE THE STAIR WAY APPEARS TO BE NOT SUPPORTED .

PLUMBING PLANS:

1. THE PLUMBING PORTION OF THE I.R.C. HAS NOT BEEN ADOPTED BY THE CITY. PLEASE AMMEND THE SUPPLY FIXTURE UNITS TO REFLECT THE STATE PLUMBING CODE ( '94 U.P.C. WITH SOME STATE AMMENDMENTS ) .

2. PROVIDE THE FIXTURE UNITS OF THE EXISTING DWELLING AND TOTAL DEVELOPED LENGTH OF THE NEW WATER DISTRIBUTION SYSTEM IF TIEING INTO THE EXISTING WATER SYSTEM .

3. PLEASE CLARIFY THE "R.V. RISER".

4. PLEASE CORRECT THE PLUMBING NOTE REFERRING TO THE 2000 I.R.C. THE STATE PLUMBING CODE IS APPLICABLE.

MECHANICAL PLANS:

1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC.

2. THE DWELLING MUST BE PROVIDED WITH HEATING CAPABLE OF MAINTAINING A ROOM TEMPERATURE OF
68 DEGREES AT A POINT 3' ABOVE THE FLOOR PER R303.6.

3. PLEASE PROVIDE A RETURN AIR .

ELECTRICAL PLANS:

1. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED
OUTLET BOXES SHALL BE USED, PER E4001.6.

2. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11.

3. SHOW LOCATIONS OF SMOKE DETECTORS PER R317. NOTE THAT ALL SMOKE DETECTORS MUST BE
INTERCONNECTED WITH A POWER SOURCE FROM THE BUILDING WIRING, AND SHALL BE EQUIPPED WITH
BATTERY BACKUP.



IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110


NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/03/2003 TAMI ACHONG OUT TO CUSTOMER Completed