Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T03CM00316
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/04/2003 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Denied | 1) Resolve conflicting information on natural gas pipe sizes. a) Sheet PBM-4 shows 4" NG line across roof to MAU-1, 2, 3, and 4. b) Detail 5, Sheet M4 shows a 3" NG line up to MAU-1, 2, 3, and 4. c) Detail 5, Sheet M4 shows a 1-1/2" NG line up to OAU-01. d) Note 5, Sheet M1 calls out a 1" NG line up to OAU-01. 2) Indicate termination point of existing drain being used to drain OAU-1 and AC-01. 3) Provide special inspection of breathing air system. |
| 04/04/2003 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 04/21/2003 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/22/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |