Permit Number: T03CM00268
Parcel: 133243740

Address:
280 N PANTANO RD

Review Status: Completed

Review Details: 3RD PARTY REVIEW-REVISION/OTHER

Permit Number - T03CM00268
Review Name: 3RD PARTY REVIEW-REVISION/OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/25/2003 STANTEC 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied SCOPE OF REVIEW:

The scope of this review covers Architectural, Structural, Plumbing, Mechanical and Electrical. All features were checked only to the extent allowed by the submittal provided. All portions of the project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL:

q There are no general comments to be addressed.

STRUCTURAL:

q The truss drawing design at the entry canopy does not reflect the structural drawings (or the architectural drawings). The truss drawing package indicates that the open web wood trusses are to bear on wood glue-laminated beams. Where are these glue-laminated beams shown in the building design drawings? Do these glue-laminated beams bear upon the steel wide flange beams at the perimeter of the entry canopy? How do these glue-laminated beams attach to the wide flange beams? Please clarify.

q In the lower right corner of Sheet 2 of 2 (the large format sheets), there is reference to a W12 x 16. Sheet S3 indicates that this beam is a W16 x 31. Please correct the descrepancy.

-End of Review-

Final Status

Task End Date Reviewer's Name Type of Review Description
07/25/2003 ELAINE ROSE OUT TO CUSTOMER Completed