Permit Number: T03CM00187
Parcel: 10319002N

Review Status: Completed

Review Details: OTHER

Permit Number - T03CM00187
Review Name: OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/10/2003 ELIZABETH EBERBACH ENGINEERING REVIEW Denied SUBJECT: 2791 West Desert Shadows Place Engineering Review
REVIEWER: Elizabeth Eberbach
DATE: March 10, 2003
ACTIVITY NUMBER: T03CM00187

SUMMARY: The residential site plans were received and reviewed by Engineering on March 10, 2003. Engineering does not recommend approval of the site plan until the following items are addressed.

SITE PLAN COMMENTS:
1) City of Tucson Development Standards (DS) Section No.2-02.2.1.A.15: The wash along the northeast side of the lot is also called out on FIRM panel 1619K. Delineate the FEMA special flood hazard area limits per this panel and label this wash (Camino De Oeste Wash) as Zone A on site plan.
2) DS Sec.2-02.2.1.A.22: Label the wash at northwest portion of site as an E.R.Z. Wash; label this area as a No Disturb Natural Area, or provide E.R.Z. submittal with drainage report discussing the floodplain and any proposed encroachment.
3) DS Sec.2-02.2.1.A.23: It appears that some contour lines are missing and some are not legibly drawn. Assure that all contours are drawn.
4) DS Sec.2-02.2.1.A: Scale of drawing shall be accurate for review purposes.
5) DS Sec.2-02.2.1.A.5: Lengths for property data are not scaleable. Clarify or revise data (lengths and area, if applicable) for property boundaries.
6) Land Use Code Article II Division 8 (LUC) Sec.2.8.1.10.A.1: After clarifying contour delineations, and adding any missing contour lines, update A.C.S. calculation.
7) DS Sec.2-12.2.3.A: Address the following proposed disturbed area:
a) Delineate and label the total proposed disturbed area;
b) Label any areas of future disturbance (i.e. future pool area or gazebo);
c) Show a calculation for the disturbed area in square feet and as a percentage of total lot area;
d) Dimension minimum distances from wash centerlines or top of embankments to the proposed disturbed area.
e) If the proposed disturbed area is more than 1 acre, the project is subject to the new NPDES requirements for NOI and Stormwater Pollution Prevention Plans, and you would need to contact Loren Makus, 791-4251 for submittal requirements.
f) LUC Sec.2.8.1.6.A.2.a.2: If not part of a subdivision, the lot must comply with Columns A, B, and D of Table 2.8.1-I. The amount of grading permitted is indicated in Column D of Table 2.8.1-I, based on the area of the lot, Column B.
8) LUC Sec 2.8.1.6.A.1: All areas of 15% or greater shall be delineated.
9) LUC Sec.2.8.1.7.C: Designate Natural Areas on the lot and exclude from development.
10) LUC Sec.2.8.1.6.A.2.a.1: Grading may occur within the buildable area and access to the buildable area.
11) DS Sec.2-02.2.1.A.33: Show location of existing fire hydrants within 300 feet of the site boundaries.
12) DS Sec.2-02.2.1.A.20: Show all existing easements and recordation information (docket & page), locations, widths, and purposes shall be included. If the easement is not in use, abandoned, or proposed for abandonment, so indicate.
13) DS Sec.2-02.2.1.A.32: Show refuse container location, size, and access thereto fully dimensioned.

Resubmittal is required and should address all the above items. Submit the revised site plan. For questions or to set up a meeting, call me at 791-5550, extension 2204.

Elizabeth Eberbach, PE
Civil Engineer
Engineering Section
Development Services
03/11/2003 DAVID RIVERA ZONING REVIEW Denied See Engineering review comments related to HDZ and ERZ. Address all comments, revise the drawing appropriately, and resubmit for Engineering and Zoning review. The drawing should be drawn at a scaleable engineering scale.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/11/2003 TAMI ACHONG OUT TO CUSTOMER Completed