Permit Number: T03CM00154
Parcel: 13707044A

Address:
5201 S 12TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T03CM00154
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/02/2003 JIM EGAN FIRE REVIEW Approved
04/15/2003 LOREN MAKUS SANITATION REVIEW Passed
04/15/2003 LOREN MAKUS ENGINEERING REVIEW Denied DATE: April 18, 2003
TO: Mr. Steve Corrales
SUBJECT: El Guero Canelo Site Plan Review
REVIEWER: Loren Makus
ACTIVITY NUMBER: T03CM00154

SUMMARY: The Site Plan, Grading-Paving Plan and Drainage Report were received by Engineering on April 1, 2003. Development Services Department Engineering Division has done a review of the site plan. Only the site plan sheet C-1 was reviewed. The site plan was not approved. Please address the following comments.

Site Plan Comments:
1) Provide fully dimensioned layout of handicapped and standard spaces including all of the dimensions (A-G) described in Table 1 of Development Standard No. 3-05.0. Provide typical space details for both standard and handicapped spaces. (DS 2-02.1.A.8)
2) Show how maneuverability requirements for access to the loading space and for solid waste service vehicles has been met. At the loading zone, provide three-foot curb setback for wall clearance. (DS 2-02.1.A.14 and 2-02.1.A.8.23)
3) Provide line of sight distances per DS 3-01.53 for MS&R Arterial Street 12th Avenue for existing and future sight visibility triangles. (DS 2-02.1.A.10)
4) Show drainage pattern flow arrows, any proposed finish floor elevation and finish grades on site plan. (DS 2-02.1.A.16)
5) Provide estimated cut and fill quantities. (DS 2-02.1.A.17)
6) Show existing contours on site plan. (DS 2-02.1.A.23)
7) Clarify the location of the pole for the pole mounted light fixture shown at the south parking area. The pole cannot be in a parking space including the area behind the wheel stop. (DS 2-02.1.B)
8) Label 12th Avenue as an MS&R street. (DS 2-02.1.A.19)
9) Show all easements with recordation information. (DS 2-02.1.A.20)
10) Show locations of sewer lines. (DS 2-02.1.A.20)
11) Show sidewalk scuppers on site plan in accordance with the drainage report. (DS 2-02.1.A.21)
12) Give dimensions for the water harvesting areas in accordance with the drainage report. (LUC 3.7.4)
13) Provide all details that are referenced on the site plan. (DS 2-02.1.B)
14) Update reference to project number. (T01CM00328).
15) Any landscaping plan shall show that no structure or vegetation shall be placed within sight visibility triangles at heights between 30 inches and 72 inches.

Revise the site plan to address all of these comments and resubmit two copies for review. Include a letter explaining how each comment has been addressed. A grading application submittal will be required. When the site plan is approved, submit application for a grading permit.


Loren Makus
Senior Engineering Associate
Engineering Division
Development Services
04/30/2003 DAN CASTRO HANDICAP-SITE REVIEW Denied Refer to Zoning Review comment number two (2).
04/30/2003 DAN CASTRO ZONING REVIEW Denied COMMENTS: Provide a response letter with the next site plan submittal that states how all the Zoning Review Section comments were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Note the recordation information (width, docket and page) for the pedestrian easement along Utah Street.
D.S. 2-02.2.1.A.20

2. Provide a disabled parking space detail,which includes the access aisle and ramps. Refer to ICC/ANSI A117.1-1998 for disable parking space requirements.
D.S. 2-02.2.2.A.3

3. Note the recordation information (width, docket and page) for the future right-of-way along 12th Avenue which has been dedicated to the City..

4. All requested revisions must be made to the site and landscape plans for consistency.
D.S. 2-07.2.1.A

If you have any questions about this transmittal, please call Dan Castro, (520) 791-5608.
05/01/2003 JOE LINVILLE NPPO REVIEW Passed Submit NPPO PLan or application for exception. DS 2-15, LUC 3.8.
05/01/2003 JOE LINVILLE LANDSCAPE REVIEW Approved A landscape plan is required. DS 2-07.2.0

Landscaping and screening regulations of LUC 3.7. apply to the entire site.

Landscaping is required to meet applicable standards. DS 2-06.0

The plans will not be accepted for review without the required landscape plan. An OK to submit from the landscape Section is required.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/06/2003 TAMI ACHONG OUT TO CUSTOMER Completed