Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T03CM00108
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/03/2003 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Denied | Site Plan 1. Indicate all existing and proposed roof slopes and downspouts running under sidewalk. D.S. 2-02.2.1.6 |
| 02/03/2003 | DOUG WILLIAMS | SANITATION | REVIEW | Passed | |
| 02/04/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 02/11/2003 | DAN CASTRO | HANDICAP-SITE | REVIEW | Denied | The last approved site plan does not show the two handicap parking spaces shown on the proposed site plan. Please provide a fully dimensioned disabled parking space detail, which complies with ICC/ANSI A117.1 sections 406 and 502 curbs, ramps, and parking spaces. |
| 02/11/2003 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. a) Per Pima County Assessors Records, the site is comprised of two separate parcels which must be combined by providing a copy of the recorded City of Tucson Lot Combination Covenant and a copy of the approved Pima County Assessors Tax Combination form. Attached to the yellow site plan card is a copy of the City of Tucson Lot Combination Covenant. b) Note the legal description of the property. D.S. 2-02.2.1.A.2 2. a) The code checklist on sheet A.1 notes two different square footages for the new addition. The gross floor area, % increase, parking, and tenant floor area calculations all indicate a square footage of either 694 S.F. or 964 S.F. Please revise for consistency. b) Note the proposed building height. D.S. 2-02.2.1.A.6/ D.S. 2-02.2.2.A.2, .3, .4, .6 3. a) The last approved site plan does not show the three (3) parking spaces east of the addition in the proposed configuration. Fully dimension the parallel vehicle parking spaces and 90 degree parking space located east of the addition. b) The last approved site plan does not show the two handicap parking spaces shown on the proposed site plan. Please provide a fully dimensioned disabled parking space detail, which complies with ICC/ANSI A117.1 sections 406 and 502 curbs, ramps, and parking spaces. D.S. 2-02.2.1.A.8 4. If applicable, provide a detail of existing and/or proposed free standing signage on the site plan. D.S. 2-02.2.2.1.A.13 5. Please note the existing and proposed use as it is listed under L.U.C. Sec. 2.6.2.2.A.10: "Medical Service - Outpatient "36" subject to: Sec. 3.5.4.8.B" D.S. 2-02.2.1.A.31 6. All requested changes must be made to the site and landscape plans. D.S. 2-07.2.1.A |
| 02/14/2003 | JOE LINVILLE | NPPO | REVIEW | Passed | |
| 02/14/2003 | JOE LINVILLE | LANDSCAPE | REVIEW | Passed | |
| 02/21/2003 | BLANCA ESPINO | ENGINEERING | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/28/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |
| 02/27/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |