Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T03CM00108
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/03/2003 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Denied | Site Plan 1. Indicate all existing and proposed roof slopes and downspouts running under sidewalk. D.S. 2-02.2.1.6 |
| 02/04/2003 | JIM EGAN | FIRE | REVIEW | Approved | |
| 02/13/2003 | MARTIN HAEBERLE | BUILDING-COMMERCIAL | REVIEW | Denied | 1. Level 1 special inspections to be performed by an approved third party inspection company. Revise general note 2. Floor live load for mezzanine to be a minimum of 125 pounds per square foot per Table 1607.1 IBC. Revise calculations and plans were necessary. 3. Storage room to be separated by a one-hour fire barrier. Provide listed assemblies and locations. Note: bearing walls supporting rated floor ceiling assemblies also to be one hour rated. 4. Mezzanine is required to have one means of egress. Provide a stair detail per section 1003.3.3 and structural calculations complying with Table 1607.1 IBC. 5. Minimum clear room height of 7 feet required for a mezzanine. Reference section 505 IBC. Revise plan 6. Provide an approved guardrail for mezzanine. |
| 02/27/2003 | ROBERT SHERRY | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 02/27/2003 | LINDA BUCZYNSKI | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 02/27/2003 | DAVID RIVERA | ZONING | REVIEW | Denied | Site Plan needs approval prior to Zoning approval of building plans. |
| 02/27/2003 | ROBERT SHERRY | MECHANICAL-COMMERCIAL | REVIEW | Denied | 1. Provide approved combination fire/smoke dampers for protection of ducts and penetrations of fire resistive walls and ceilings. Reference Section 715, IBC. 2. Provide access to roof hatch. 3. Provide calculations for the addition to show compliance to the International Energy Conservation Code, 1998. 4. Note on sheet M.1 indicates the mechanical design for this addition was done by B&J Refrigeration. This is in violation of the regulatory provisions of the Arizona Board of Technical Registration: " A registrant shall not sign, stamp or seal any professional documents not prepared by the registrant or a bona fide employee". |
| 02/27/2003 | ROBERT SHERRY | WATER | REVIEW | Approved | |
| 02/27/2003 | GERRY KOZIOL | WWM | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/28/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |
| 02/27/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |