Permit Number: T03CM00078
Parcel: 106031160

Review Status: Completed

Review Details: SITE

Permit Number - T03CM00078
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/29/2003 BLANCA ESPINO FLOODPLAIN REVIEW Denied SEE ENGINEERING FOLDER FOR COMMENTS.
01/29/2003 BLANCA ESPINO SANITATION REVIEW Denied SEE ENGINEERING FOLDER FOR COMMENTS.
01/30/2003 JIM EGAN FIRE REVIEW Approved
03/12/2003 BLANCA ESPINO ENGINEERING REVIEW Denied Site Plan
1. Indicate project address on sheet XI.I. D.S. 2-02.2.1.3

2. Indicate location map. D.S. 2-02.2.1.4

3. Indicate all existing and proposed buildings/structures roof slopes and downspouts. D.S. 2-02.2.1.6

4. Indicate existing and future sight visibility triangles. D.S. 2-02.2.1.10

5. Indicate limits of the 100-year floodplain and water surface elevation. D.S. 2-02.2.1.15

6. Indicate drainage patterns, proposed finish floor elevation(s) and finish grades. Refer to Figure 5 of Drainage Report for FFE for new building. D.S. 2-02.2.1.16

7. Indicate estimated cut and fill quantities. D.S. 2-02.2.1.17

8. Indicate if streets are "Public" or "Private".. D.S. 2-02.2.1.18

9. Indicate existing or future right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. D.S. 2-02.2.1.19

10. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines. D.S. 2-02.2.1.21

11. Indicate existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number. D.S. 2-02.2.1.23

12. Indicate refuse container location, size and access thereto fully dimensioned. D.S. 2-02.2.1.32



Drainage Report
1. Drainage Report is acceptable for Site Plan review.
03/21/2003 DAN CASTRO HANDICAP-SITE REVIEW Denied Refer to Zoning Review comment number five (5).
03/21/2003 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Note the existing and proposed land uses as they are listed under L.U.C. Sec. 2.3.5.2. Please include the proposed land use class, development designator, and applicable "subject to" sections under the proposed land use note. All calculations and building setbacks may not be verified for compliance until this information is noted on the plan. Additional comment may be forthcoming upon resubmittal of this plan. The following comments are based on a full code compliance review of the entire site.
D.S. 2-02.2.1.A.31

2. Provide a location map.
D.S. 2-02.2.1.A.4

3. Note the existing building height and proposed building height.
D.S. 2-02.2.1.A.6

4. Label and dimension building setbacks to all property lines.
D.S. 2-02.2.1.A.7

5. Provide a fully dimensioned typical parking space detail for both standard and handicap parking spaces, together with access thereto.
D.S. 2-02.2.1.A.8

6. a) Provide a fully dimensioned bicycle parking space detail. Refer to D.S. 2-09 for design criteria.
b) Indicate graphically and by note the location of the bicycle parking spaces.
D.S. 2-02.2.1.A.9

7. Label and dimension sight visibility triangles.
D.S. 2-02.2.1.A.10

8. Dimension the width of the PAAL and the ingress/egress point.
D.S. 2-02.2.1.A.11

9. Dimension the width of the on-site pedestrian circulation system. Refer to D.S. 2-08 for on-site pedestrian circulation requirements.
D.S. 2-02.2.1.A.12

10. If applicable, provide a detail of existing and/or proposed free standing signage and outdoor lighting on the site plan.
D.S. 2-02.2.1.A.13/ D.S. 2-02.2.1.A.25

11. Add the following general note: "Loading zone not required for this project."
D.S. 2-02.2.1.A.14

12. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference.
D.S. 2-02.2.1.A.20

13. Label the zoning classification (R-2) for the adjacent properties on the plan.
D.S. 2-02.2.1.A.28

14. Indicate graphically and by note the location of the refuse container.
D.S. 2-02.2.1.A.31

15. Provide the floor area ratio calculation and lot coverage calculation.
D.S. 2-02.2.2.A.3

16. Provide the building area expansion calculation.
D.S. 2-02.2.2.A.6

17. All requested changes must be made to the site and landscape plans.
D.S. 2-07.2.1.A
03/21/2003 JOE LINVILLE NPPO REVIEW Denied Submit a native plant preservation plan per DS 2-15.0 in compliance with the provisions of LUC 3.8. See DS 2-15.2.0 for additional options.
03/21/2003 JOE LINVILLE LANDSCAPE REVIEW Denied Submit a landscape plan per DS 2-07 in compliance with LUC 3.7 and DS 2-06.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/24/2003 LISA LESNY OUT TO CUSTOMER Completed