Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T03CM00032
Parcel: 137055240

Review Status: Completed

Review Details: 3RD PARTY REVIEW-REVISION/OTHER

Permit Number - T03CM00032
Review Name: 3RD PARTY REVIEW-REVISION/OTHER
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/29/2003 WILDAN 3RD PARTY REVIEW-COMMERCIAL REVIEW Denied GENERAL COMMENTS:

1. This project has been reviewed for conformance with the 2000 IBC, 1997 UAC, 2000 IMC, 1998 IECC, 1999 NEC codes with local modifications, and the 1994 UPC with State of Arizona Amendments. Any revisions to this plan will require an additional review and approval by Willdan.


ARCHITECTURAL COMMENTS:

The architectural portion was not a part of this review.


STRUCTURAL COMMENTS:

1. The steel joist manufacturer's ICBO ES Report PFC-5808 acknowledges compliance with the 1997 UBC. The joist product engineer sealed cover letter only acknowledges design compliance with the manufacturer's bill of materials. The cover letter's disclaimer, "The Professional Engineer's Seal is not intended to certify or imply that the building does or does not conform to any National, State, or Local Building Codes," does not evidence design code compliance. Therefore, the product engineer's sealed design cover letter shall be revised to evidence its responsibility, and certify that the steel joist designs and calculations are in compliance with the jurisdiction's adopted 2000 IBC, and the Steel Joist Institute Specifications, 1994 edition. The disclaimer shall be deleted. Reference IBC Sections 102.4, 106, and 2206.


PLUMBING COMMENTS:

The plumbing portion was not a part of this review.


MECHANICAL COMMENTS:

The mechanical portion was not a part of this review.


ELECTRICAL COMMENTS:

The electrical portion was not a part of this review.


ENERGY CODE COMMENTS:

The energy code portion was not a part of this review.


ACCESSIBILITY COMMENTS:

The accessibility portion was not a part of this review.

Final Status

Task End Date Reviewer's Name Type of Review Description
08/29/2003 ELAINE ROSE OUT TO CUSTOMER Completed