Permit Number: T03BU03161
Parcel: 13419042C

Review Status: Completed

Review Details: GRADING

Permit Number - T03BU03161
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/12/2004 PAUL MACHADO ENGINEERING REVIEW Denied To: Ann Price
GDA
250 E. Broadway Blvd., Ste, 200
Tucson, Arizona 85711
SUBJECT: Starbucks Coffee
Grading Plan T03BU03161 (first Review)
T14S, R15E, Section 17

RESUBMITTAL REQUIRED: Grading Plan

The Grading Plan (GP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Grading Plan:

1. Please include a response letter to the comments along with the corrected copies with re-submittal.
2. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting"
3. List administrative address/site address on plans.
4. List the consulting engineer and the owner/developer on the plans with the pertinent information.
5. Show Development plan number on all sheets per D.S. 2-02.2.1.29.
6. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed.
7. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information.
8. Sidewalks are required for the portion of the property fronting the street and also to the building per D.S. 3-01.3.3.
9. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
10. Please correct the Section, township and range on the location map.
11. The drive-thru lane does not drain, please revise.



Drainage Statement:

1. The DS is accepted.

If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul P. Machado
Senior Engineering Associate
City of Tucson/Development Services Department
201 N. Stone Avenue
P.O. Box 27210
Tucson, Arizona 85726-7210
(520) 791-5550 x1193 office
(520) 879-8010 fax
01/12/2004 PATRICIA GEHLEN ZONING REVIEW Denied Zoning
1/12/2004
Zoning will review and approve the grading plans once Engineering has approved.
01/15/2004 Joseph Linville NPPO REVIEW Approv-Cond Submit grading plan for NPPO approval stamps after Engineering approval.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/16/2004 CINDY AGUILAR OUT TO CUSTOMER Completed
01/15/2004 ANGIE SHOFFSTALL REJECT SHELF Completed