Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T03BU03161
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/12/2004 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Ann Price GDA 250 E. Broadway Blvd., Ste, 200 Tucson, Arizona 85711 SUBJECT: Starbucks Coffee Grading Plan T03BU03161 (first Review) T14S, R15E, Section 17 RESUBMITTAL REQUIRED: Grading Plan The Grading Plan (GP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Grading Plan: 1. Please include a response letter to the comments along with the corrected copies with re-submittal. 2. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting" 3. List administrative address/site address on plans. 4. List the consulting engineer and the owner/developer on the plans with the pertinent information. 5. Show Development plan number on all sheets per D.S. 2-02.2.1.29. 6. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S. 3-01.4.4. If the location(s) of the roof scuppers have not yet been decided, add a general note indicating sidewalk scuppers (per COT/SD) will be used when the roof scuppers locations have been designed. 7. A permit or a private improvement agreement will be necessary for any work performed within the Right-of-way. Contact Permits and Codes at (520) 791-5100 for permit information. 8. Sidewalks are required for the portion of the property fronting the street and also to the building per D.S. 3-01.3.3. 9. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. 10. Please correct the Section, township and range on the location map. 11. The drive-thru lane does not drain, please revise. Drainage Statement: 1. The DS is accepted. If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us Paul P. Machado Senior Engineering Associate City of Tucson/Development Services Department 201 N. Stone Avenue P.O. Box 27210 Tucson, Arizona 85726-7210 (520) 791-5550 x1193 office (520) 879-8010 fax |
| 01/12/2004 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | Zoning 1/12/2004 Zoning will review and approve the grading plans once Engineering has approved. |
| 01/15/2004 | Joseph Linville | NPPO | REVIEW | Approv-Cond | Submit grading plan for NPPO approval stamps after Engineering approval. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/16/2004 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |
| 01/15/2004 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |