Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T03BU02538
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2003 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | SUBJECT: Site and Drainage Report Review REVIEWER: Doug Williams DATE: 30 October 2003 ACTIVITY NUMBERS: T03CM01365/T03BU02538 T14S, R14E, Section 30 SUMMARY: Engineering Section has reviewed the Site and Grading Plan and Drainage Report resubmittals received on 2 October 2003. All comments from the August 15, 2003 engineering review have not been adequately addressed. Approval is not recommended at this time - resubmittal is required. Please address the following comments listed below, and provide a response letter specifically addressing each comment. DRAINAGE REPORT: a) Provide detention basin design requirements for a basin outlet weir with details and dimensions, fully labeled and discussed in the report. Specific attention should be given to the items outlined in sections 2.3.1.6 A 4 (a), B, and C, and sections III and V of the Pima County/City of Tucson Stormwater Detention/Retention Manual (DS 10-01.0). The report must demonstrate that post-developed flood peaks for the 2- 10- and 100-year events do not exceed pre-developed peaks. Specific information should be referenced in sections 3.3.2, 3.3.3, 3.5.2 and 3.6 of the Detention/Retention Manual (Section III, noted above and in previous comment letter). It is important that additional design guidelines discussed in these sections are addressed in the report, particularly outflow hydrograph determination, erosion control downstream of outlets, embankments and emergency spillway requirements; b) Describe and provide hydraulic calculations for the proposed swale along the western property line, to include provision of a cross section of the swale, fully dimensioned and labeled, per section 2.3.1.5 C (DS 10-02.0); c) Please provide the summaries to be included in the basin checklist for the annual inspection report, in accordance with section 2.3.1.6 C 2 a & b (DS10-02.0); d) Geotechnical and drainage report considerations and recommendations should address minimum structure setbacks from the retention/detention basin and associated discharges, to ensure no adverse impact will occur to adjacent structures and/or properties as a result of this development; SITE PLAN COMMENT: The previous comment, "Provide sidewalk scuppers for a minimum of 10-year flow conveyance under sidewalk areas (D.S. 2-08.4.1 E and 3-01.4.4 F2)" does not appear to have been addressed on the Site Plan. Please depict appropriate scupper locations on the plan with labeling. GRADING PLAN COMMENTS: a) Include general grading/construction notes, in accordance with Chapter 36, 2000 IBC (excavation and grading). The consultant should direct special attention to the sections pertaining to cuts, fills, grading setbacks, slope treatments and geotechnical report requirements and recommendations. This document may be accessed at: http://www.ci.tucson.az.us/dsd/2000_IBC_Amendments.pdf; b) Provide a legend and cross-sections fully labeled and dimensioned for the basin and each perimeter, grading limits and slope treatments with reference to riprap average diameter (D50) and thickness (t). c) Include basin, drainage swale and scupper details, fully dimensioned, and labeled. Additional grading plan comments may be necessary, upon resubmittal. If you have any questions, I can be reached at 791-5550, ext. 1189 or Dwillia1@ci.tucson.az.us. Douglas Williams Sr. Engineering Associate Engineering Division Development Services Department |
| 10/30/2003 | Joseph Linville | NPPO | REVIEW | Passed | |
| 11/07/2003 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | Zoning 11/7/2003 Grading plans will be reviewed and approved once Engineering has approved. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/21/2003 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |
| 11/21/2003 | MONICA VALDEZ | REJECT SHELF | Completed |