Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T03BU01729
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/07/2003 | PATRICIA GILBERT | NPDES | REVIEW | Passed | Less than one acre of disturbance. |
| 07/07/2003 | PATRICIA GILBERT | ENGINEERING | REVIEW | Denied | DATE: July 3, 2003 ACTIVITY NUMBER: T03BU01729 PROJECT NAME: Office Building Renovation for Gene Rossitti PROJECT ADDRESS: 529 North 6th Avenue PROJECT REVIEWER: Patricia Gilbert The following items must be revised or added to the Grading Plan. Please include a response letter with the next submittal that states how all comments have been addressed. RESUBMITTAL REQUIRED: GRADING PLAN 1. Add a note on the plan, "All roof down spouts will be routed under any adjacent sidewalk." Sidewalks must be flood free for up to the 10-yr. event. The plan shows sidewalks adjacent to the building on the north, east, and west sides. If the intention is to have the one foot wide planter on the east side of the building contain the entire roof drainage from this side of the building provide appropriate drainage calculations. Otherwise, provide appropriate sidewalk scuppers. DS 2-08.4.1.E. 2. Show roof drainage (flow arrows). DS 2-02.2.1.A.16 3. The proposed sign at the south parking lot exit encroaches into the FEMA floodplain. Any proposed development in the floodplain requires a Flood Use Permit. Either locate all development outside the floodplain or submit a Flood Use Permit application with the next submittal. Flood Use Permit approval is required prior to Grading Plan approval. Tucson Code Chapter 26 4. The Site Plan and Grading Plan have the same sheet numbers. Perhaps the intention was for the Grading Plan to be labeled G1. Re-label. 5. The Site Plan is currently in the review process. Any changes made to the Site Plan must be reflected on the Grading Plan. The Grading Plan will not be approved until the Site Plan is approved. |
| 07/24/2003 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | The Grading Plan cannot be approved until the Site Plan is approved. |
| 07/30/2003 | JOE LINVILLE | NPPO | REVIEW | Denied | The grading application will be reviewed for compliance with the site/landscape/NPPO plans when approved. Inspections may be required prior to grading. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/31/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |
| 07/30/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |