Permit Number: T03BU01254
Parcel: 120076160

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING

Permit Number - T03BU01254
Review Name: RESIDENTIAL BLDG/ZONING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/20/2003 MICHAEL ST. PAUL ZONING REVIEW Approved
05/20/2003 MICHAEL ST. PAUL NPPO REVIEW Passed
06/04/2003 DAVE WITT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T03CM01254

6/5/03 137 W. PENNSYLVANIA DR.

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED
FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE.

2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.

4. ALL ENGINEERS AND ARCHITECTS INVOLVED IN THE DESIGN OF THE STRUCTURE ARE TO SEAL THE
RELATED SHEETS OF PLANS, DETAILS AND CALCULATIONS. THIS IS IN ACCORDANCE WITH THE RULES OF
THE STATE BOARD OF TECHNICAL REGISTRATION.

SITE PLAN:

1. INDICATE THE LOCATION OF THE ONE HOUR FIRE WALL AT 2'-8" FROM THE PROPERTY LINE.

FOUNDATION PLAN:

1. PROVIDE THE SIZE OF THE FOOTINGS UNDER THE MASONRY COLUMNS.

FLOOR PLANS:

1. PROVIDE DIMENSIONS FOR THE PORCH WITH MASONRY COLUMNS.

2. PROVIDE THE FIRE WALL AT THE BUILDING EDGE LOCATED LESS THAN 3'-0" FROM THE PROPERTY LINE.

3. PLEASE NOTATE THE RELOCATED GAS LINE IS TO BE NOT LESS THAN 6" ABOVE GRADE.

STRUCTURAL PLANS:

1. ROOF FRAMING PLAN, IS DETAIL 6/D1 THE DETAIL TO BE USED FOR THE RAFTER TO BEAM CONNECTION OR 15/D1?

2. SPECIFY LUMBER GRADE AND SPECIES.







SECTIONS - DETAILS - MISC. NOTES:

1. 2&3/D1, DEFINE "C.F.B.".

2. 3/D1, PROVIDE FOOTING DIMENSIONS.

3.6/D1, WOULD YOU CONSIDER A GLB5AX WITH A 3 5/8" "W" DIMENSION INSTEAD OF THE MODIFIED "CC" CAP? SIMPSON HAS NO SPEC FOR THIS MODIFICATION.

4. 7/D1, PLEASE DIMENSION THE WALL HEIGHT.

5. 7/D1, PLEASE SPEC THE WALL COVERING.

6. 7/D1, PROVIDE LATERAL BRACEING FOR THE WALL. A CANT STRIP?

7. 8/D1, PROVIDE THE SPACEING FOR THE ANCHOR BOLTS.

8. 9/D1, PROVIDE THE DIMENSIONS OF THE SCUPPER.

9. 13/D1, SIMPSON "PB" ARE TO BE SET FLUSH WITH THE CONCRETE WHICH REQUIRES A PRESSURE TREATED OR RED WOOD POST. WOULD YOU CONSIDER AN "AB66" WITH A ½"X 8" ANCHOR BOLT?






IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WITT @ 791-5550 EXT. 1110

Final Status

Task End Date Reviewer's Name Type of Review Description
06/11/2003 LISA LESNY OUT TO CUSTOMER Completed
06/04/2003 ANGIE SHOFFSTALL REJECT SHELF Completed