Permit Review Detail
Review Status: Completed
Review Details: 3RD PARTY REVIEW-COMMERCIAL TI
Permit Number - T03BU00947
Review Name: 3RD PARTY REVIEW-COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/13/2003 | EROSE1 | WWM | REVIEW | Needs Review | |
05/13/2003 | EROSE1 | WATER | REVIEW | Needs Review | |
05/13/2003 | EROSE1 | FIRE | REVIEW | Needs Review | |
05/13/2003 | WILDAN | 3RD PARTY REVIEW-COMMERCIAL | REVIEW | Denied | ARCHITECTURAL COMMENTS: 1. No comments. STRUCTURAL COMMENTS: 1. The proposed structure is welded and requires the installation of expansion anchors into hardened concrete. Both of those structural procedures require special inspection. Please provide City of Tucson required documentation for special inspections. Reference IBC 106 and IBC 1704. 2. Five letter sized structural sketches showing the proposed construction are not sealed. Please seal each sheet or provide a full size drawing for incorporation with the architectural drawings. Reference IBC 106. 3. The proposed expansion anchor material specification is not identified. Please identify ICBO Evaluation Report # that is in compliance with the 2000 IBC structural provisions. Reference IBC 1604.4. |
05/13/2003 | WILDAN | 3RD PARTY REVIEW-COMMERCIAL | AT 3RD PARTY OFFICE | Passed | ARCHITECTURAL COMMENTS: 1. No comments. STRUCTURAL COMMENTS: 1. The proposed structure is welded and requires the installation of expansion anchors into hardened concrete. Both of those structural procedures require special inspection. Please provide City of Tucson required documentation for special inspections. Reference IBC 106 and IBC 1704. 2. Five letter sized structural sketches showing the proposed construction are not sealed. Please seal each sheet or provide a full size drawing for incorporation with the architectural drawings. Reference IBC 106. 3. The proposed expansion anchor material specification is not identified. Please identify ICBO Evaluation Report # that is in compliance with the 2000 IBC structural provisions. Reference IBC 1604.4. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/13/2003 | ELAINE ROSE | OUT TO CUSTOMER | Completed |