Permit Number: T03BU00727
Parcel: Unknown

Address:
3333 N WALNUT AV

Review Status: Completed

Review Details: GRADING

Permit Number - T03BU00727
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/21/2004 PATRICIA GEHLEN ZONING REVIEW Denied Zoning
2/2/2004
Zoning may not review and approve the grading plans until a copy of the approved tentative plat is included in the submittal package.
01/30/2004 Andrew Connor NPPO REVIEW Denied Submit the approved tentative plat, NPP & Landscape plans.
02/02/2004 Laith Alshami ENGINEERING REVIEW Denied Laith Alshami, Engineering Comments, 02/02/2004

1- Provide the parcel dimensions and bearings on the grading plan. The horizantal control plan can be made part of the grading plan to satisfy this requirement.
2- Dimension the Common Areas and all lots. The horizantal control plan can be made part of the grading plan to satisfy this requirement.

Laith ALshami, Floodplain Comments, 02/02/2004

1- Provide the width of the proposed the erosion control riprap pads downstream of the proposed sidewalk scuppers (including the width of the grouted sections).
2- Please be advised that based on the City's previous experience with grouted rip rap, 6" thick grout may be damaged easily, which can undermine the purpose of installing it and may impose additional maintenance cost on the lot owners in the future.
02/02/2004 Laith Alshami ENGINEERING REVIEW Denied The Stormwater Pollution Prevention Plan is approved.
Loren Makus
Senior Engineering Associate
2-2-04

Final Status

Task End Date Reviewer's Name Type of Review Description
02/03/2004 TAMI ACHONG OUT TO CUSTOMER Completed
02/02/2004 ANGIE SHOFFSTALL REJECT SHELF Completed