Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T02OT01986
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/19/2002 | BLANCA ESPINO | FLOODPLAIN | REVIEW | Approved | 12-20-2002 FLOODPLAIN USE PERMIT NO. T02OT01986 ADDRESS: FREMONT ESTATES SUBDIVISION, BK 51 PG 05, 3302 N. FREMONT AVE. PROPERTY OWNER: THERESA M. RIESS The applicant is authorized to use a portion of the City of Tucson the property described as (legal description): FREMONT ESTATE LOTS 1-5. For the purpose of renewing permit #1371 for constructing five (5) single-family residences within a FEMA floodplain. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions shall apply to this permit. (Or refer to Chapter 26 page 35) 1. All work shall conform to the attached plans and documentation which are made part of this permit. Drainage Report #2063. 2. The building shall be placed on an engineered pad, compacted to 95% density. 3. The lowest finish floor of the building in the property under this permit shall be placed upon a dirt, concrete, or similar type solid pad a minimum of Lot No. Minimum FFE Address 1 2363.62 3302 N. Fremont Ave. 2 2363.60 3314 N. Fremont Ave. 3 2363.11 3326 N. Fremont Ave. 4 2363.11 3338 N. Fremont Ave. 5 2362.13 1028 E. Halcyon Rd. feet above mean sea level, national geodetic vertical datum (NGVD), 1929 as Certified by a Registered Land Surveyor. This certification must be completed and returned to the Office of the City Engineer, Engineering Unit on the 1st floor of the County/City Public Works Building at 201 N. Stone Avenue. This certification must be completed immediately after the finished floor is constructed. Please call Engineering Office for inspection prior to any wall construction. 4. The storage tanks (12' high and 5' diameter corrugated metal culvert in an 8" concrete pad base), functioning as water harvesting & retention shall be located within the buildings outline on either the east or west side of building in order to limit any obstruction to the flow of floodwaters. 5. The access to the house via a stair or set of steps shall not block or obstruct flow of floodwaters. 6. There must be a minimum of two openings on different sides of the enclosed property. If the property has more than one enclosed area, each area must have openings to allow floodwaters to directly enter and exit. The top of the openings shall be at the level of the 100-year water surface elevation. The existing drainage patterns at the property lines shall not be obstructed. 7. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Permit #T02OT01986. For information please call 791-5550." 8. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 9. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section. (EXPIRATION DATE) Month: January Day: 11 Year: 2004 Note the final inspection or certificate of occupancy will be on hold until the Elevation Certificate is completed and returned to our office. The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/08/2003 | DELMA ROBEY | OUT TO CUSTOMER | Completed |