Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T02OT01595
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/15/2002 | MATT FLICK | FLOODPLAIN | REVIEW | Approved | November 15, 2002 FLOODPLAIN USE PERMIT NO. T02OT01595. ADDRESS: 2860 North Silverbell Road PROPERTY OWNER'S NAME: JDP Grant Silver, LLC The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as (legal description): Irr Pcl in NW4 of Section 34, T-13-S, R-13-E for the purpose of placement of fill material within the FEMA-mapped portion of the Santa Cruz River as shown on the approved tentative plat "Silver Creek II", S02-002. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions shall apply to this permit. (Or refer to Chapter 26 page 35) 1. All work shall conform to the attached plans, which are made part of this permit. 2. The existing drainage patterns at the property lines shall not be obstructed. 3. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T02OT01595. For information please call 791-5550." 4. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. 5. This permit becomes invalid and is subject to additional floodplain review, if any required development permit changes the configuration of the structure and or site development. 6. Development to conform to the approved tentative plat (S02-002) and grading plan (T02BU01699) for this development. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section. (EXPIRATION DATE) Month: 11 Day: 15 Year: 2003 APPLICANT NAME: JDP Grant Silver, LLC ADDRESS: 3567 E Sunrise Drive, Suite 219, Tucson, AZ 85715 PHONE NO.: (520) 296-8544 _____________________________ APPLICANT'S SIGNATURE DATE The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/11/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |