Permit Number: T02OT01372
Parcel: Unknown

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T02OT01372
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/12/2003 LAITH ALSHAMI FLOODPLAIN REVIEW Approved Laith Alshami, Floodplain and Engineering Review. Floodplain Use Permit for "Palomino Trail".

February 12, 2003

FLOODPLAIN USE PERMIT NO. T02OT01372
ADDRESS: 8365 E. Speedway Blvd
PROPERTY OWNER'S NAME: Pepper-Viner Investment Company

The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as:

PALOMINO TRAIL, LOTS 1 THROUGH 26 AND COMMON AREAS "A & B", PORTION OF SECTION 4, T-14-S, R-15-E, G.&S.R.M., PIMA COUNTY, ARIZONA for the purpose of installing a fill and grouted riprap in the existing Magee Wash 100-year floodplain to provide positive drainage and raise the proposed single family residences pads above the100-year floodplain.

The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit.

The following conditions shall apply to this permit.

1. All work shall conform to the attached plans which are made part of this permit.

2. All proposed fill within the outer 100 feet of the developing site (less any intervening non-developable property outside the site) shall comply with the requirements of Section 13 (Fills) of Chapter 36 - Excavation and Grading, of the City Code.

3. The proposed fill shall be compacted to a minimum of 95% density, extending only to the extent shown on the attached plan.

4. The Developer shall require a separate Floodplain Use Permit and Elevation Certificate for each lot that is proposed in the existing 100-year floodplain, when the lot plot plans for each of the impacted lots are submitted for construction permits. Alternatively, it is preferable to include the proposed final grading (pad elevations) of the impacted lots as part of this development assurances.

5. The existing drainage patterns at the property lines shall not be obstructed.

6. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Use Permit No. T02OT01372. For information please call 791-5550."

7. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties.

8. This permit becomes invalid and is subject to additional floodplain review, if any required development permit (s') changes the configuration of the structure and or site development.

9. Any walls to be constructed within the floodplain will require a separate Floodplain Use Permit and a separate construction permit.

This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section.

(EXPIRATION DATE) Month: 02 Day: 12 Year: 2004


APPLICANT NAME: Pepper-Viner Investment Company
ADDRESS: 5633 East Grant Road
Tucson, AZ 85712
PHONE NO.: (520) 721-7964
________________________ ______________
APPLICANT'S SIGNATURE DATE

The applicant is authorized by the City Engineer to receive a floodplain use permit subject to the above referenced conditions and restrictions.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/07/2003 MONICA VALDEZ OUT TO CUSTOMER Completed