Permit Number: T02OT00751
Parcel: 129030200

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T02OT00751
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/11/2002 JIM TATE FLOODPLAIN REVIEW Denied A Flood Use Permit is denied.

Tucson Code Sec. 26-4.3
"any alteration, addition or repair to a nonconforming building or structure which would result in increasing its flood damage potential by fifty (50) percent or more shall be elevated to or above the regulatory flood elevation."

1. The construction estimate for the remodel and addition must be performed by a licensed contractor and include appropriate labor and material costs. The total new addition to the existing structure is 948 sq.ft. At an approximate construction cost of $63 per sq. ft. the cost of additions would total $59,724.

2. All additions to the structure since August 3, 1984 must be documented. The total cumulative value of all such additions and proposed additions determine the increase in flood damage potential of the structure. Please include an approved site plan showing that the structure has not been added to since 1984.

3. The supplied Appraisal Report indicates the existing depreciated value of the building is $80,163. A maximum value of all additions and proposed additions without elevating any structure is $40,081. The proposed improvements exceed this amount and do not include any previous improvements.

Final Status

Task End Date Reviewer's Name Type of Review Description
06/18/2002 MONICA VALDEZ OUT TO CUSTOMER Completed