Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T02OT00517
Review Name: FLOODPLAIN
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/04/2002 | JAMES TATE | FLOODPLAIN | REVIEW | Approved | Floodplain Use Permit # T02OT00517 April 3, 2002 Address: 2640 S. Cottonwood Lane Lot 104 Parcel No 118101230 The applicant is authorized to use a portion of the flood hazard area in the City of Tucson on the property described as Lot 104 Cottonwood MHP for the purpose of installing a moble home. The applicant agrees to comply with City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referred to below, as determined by the City Engineer, shall be grounds for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver of other requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercourse Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions shall apply to this permit. 1. All work shall conform to the attached plot plan which is made part of this permit. 2. The lowest structural member of the manufactured home placed on the property under this permit shall be placed upon a dirt, concrete, or similar type solid pad a minimum of 2384.7 feet above mean sea level, National Geodetic Verticle Datum 1929 (NGVD 1929), as Certified by a Registered Land Surveyor. This certification must be completed and returned to the Development Services Dept., Engineering Section on the 1st. floor of the County/City Public Works Building at 201 N. Stone Avenue 3. The manufactured home shall be firmly anchored to prevent flotation. Certification of the manufactured home anchoring and utility location by an agent acceptable to the City Engineer is required. 4. The manufactured home shall have the long axis parallel to the direction of flow. 5. Within 5 (five) days of issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Permit #T02OT00517. For information please call 791-5550." 6. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. This Floodplain Use Permit will be automatically revoked and becomes invalid if conditions set forth in this permit are not complied with. Also, this permit will expire one year from its date of issue. Renewal of this permit will require a new application, review and approval of that application by the City of Tucson, Development Services Department, Engineering Section. (EXPIRATION DATE) Month: 04 Day: 03 Year: 2003 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/08/2002 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |