Permit Number: T02OT00497
Parcel: 11616115B

Address:
545 W SHIBELL ST

Review Status: Completed

Review Details: FLOODPLAIN

Permit Number - T02OT00497
Review Name: FLOODPLAIN
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/26/2002 MATT FLICK FLOODPLAIN REVIEW Denied 1. Site is in AO(1) Zone. FFE must be 2' above highest adjacent grade. Show utilities (includes electric, cable, phone, etc.) to be elevated, and, indicate location and elevation on plan.

2. Fill 25' beyond building, or lesser distance if protected from erosion and certified by a registered civil engineer.

3. Plan is not detailed and is missing information needed for approval of floodplain permit. Submit together with T01CM05904 and T01CO05912, or, include sufficient site plan information on floodplain plan..

Final Status

Task End Date Reviewer's Name Type of Review Description
05/15/2002 DELMA ROBEY OUT TO CUSTOMER Completed