Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: FLOODPLAIN
Permit Number - T02OT00282
Review Name: FLOODPLAIN
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
03/04/2002 | MIKE BERGHUIS | FLOODPLAIN | REVIEW | Approv-Cond | T02OT00282 Floodplain Use Permit 1907 E. 13 th Street Tucson AZ The applicant agrees to comply with the City of Tucson Floodplain and Erosion Hazard, and Watercourse Amenities, Safety and Habitat regulations, and are particularly bound by the conditions stated below. Violation of any of the conditions stated or referenced below, as determined by the City Engineer, shall be ground for revocation of this permit. Responsibility for renewal of this permit, if necessary, is with the applicant. Issuance of this permit does not constitute a waiver ofother requirements contained in the Tucson City Code, Land Use Code, or any other Federal, State, or local regulation. No use other than as permitted herein is allowed. Additional uses allowed under City of Tucson Floodplain and Erosion Hazard Regulations and Watercoures Amenities, Safety, and Habitat regulations require the issuance of an additional Floodplain Use Permit. The following conditions shall apply to this permit. 1. All work shall conform to the attached plans, Drainage Report Kitchell Corp. Warehouse (7-4-2001) and concept Site Plan (2-21-2002). 2. Any building shall be placed on an engineered pad, compacted to 95% density,extending twent-five (25) feet beyond the buildings foundation, and as modified as per the attached approved site plan. 3. The lowest finished floor of the building in the property under this permit shall be placed upon a dirt, concrete or similar type solid pad a minimum of 2439.90 feet above mean sea level, National Geodetic Vertical Datum, (NGVD) 1929 as Certified by a Registered Land Surveyor. This certification must be completed and returned to the Office of the City Engineer, Development Services Dept, 3 rd Floor of the County/City Public Works Building at 201 N. Stone Avenue. 4. Only chain link fencing can be used to enclose this site. 5. Within five (5) days after issuance of this permit, through completion of the project, notification must be posted and maintained in a conspicuous place on the job site stating "Construction proceeding under requirements of City of Tucson Floodplain Permit No, T02OT00282. For information call 791-5550. 6. Except as approved by the City Engineer prior to the start of construction, development under this permit shall not obstruct, retard or divert the existing flow of floodwaters from or to adjacent properties. NOTE the final inspection or certificate of occupancy will be on hold until the Elevation Certificate is completed and returned to our office. |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
03/19/2002 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |