Permit Number: T02CM05889
Parcel: 13631003E

Review Status: Completed

Review Details: SITE

Permit Number - T02CM05889
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/19/2003 JIM EGAN FIRE REVIEW Approved
04/07/2003 ANY FLOODPLAIN REVIEW Approved
04/07/2003 PAUL MACHADO ENGINEERING REVIEW Denied To: George Holguin,
Architect
7878 E. Escalante Road Tucson, Arizona 85715

SUBJECT: 9750 E. Escalante Rd
Site plan T02cm05889 (First Review)
T14S, R15E, Section 35

RESUBMITTAL REQUIRED: Site Plan

The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies with resubmittal.
2. Please correct the Section number on the location map.
3. Please provide property description per D.S. 2-02.2.1.3.
4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10.
5. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11.
6. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
7. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
8. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17.
9. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
10. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
11. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27.
12. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0.
13. List the consulting engineer and the owner/developer on the plans with the pertinent information.
14. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
04/07/2003 ANY SANITATION REVIEW Denied To: George Holguin,
Architect
7878 E. Escalante Road Tucson, Arizona 85715

SUBJECT: 9750 E. Escalante Rd
Site plan T02cm05889 (First Review)
T14S, R15E, Section 35

RESUBMITTAL REQUIRED: Site Plan

The Site Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Site Plan:

1. Please include a response letter to the comments along with the corrected copies with resubmittal.
2. Please correct the Section number on the location map.
3. Please provide property description per D.S. 2-02.2.1.3.
4. Label existing and future sight visibility triangles per D.S. 2-02.2.1.10.
5. Show all points of egress and ingress including locations and width of driveways and parking area access lanes (P.A.A.L.) per D.S. 2-02.2.1.11.
6. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12.
7. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16.
8. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17.
9. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21.
10. Please provide existing topographic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23.
11. Show all fences, walls, or vegetation for screening and sight visibility by type, material, height, location and spacing per D.S. 2-02.2.1.27.
12. Show refuse container location, size, and access thereto fully dimensioned per D.S. 2-02.2.1.32 and D.S. 6-01.0.
13. List the consulting engineer and the owner/developer on the plans with the pertinent information.
14. Add note: "Depress all landscaped areas 6" maximum for water harvesting".
If you have any questions, I can be reached at 791-5550 x1193 or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
04/07/2003 PETER MCLAUGHLIN ZONING REVIEW Denied SITE PLAN TRANSMITTAL

TO: George Holguin FROM: Peter McLaughlin
PO Box 13252 Senior Planner
Tucson, AZ 85749 Dev Services Dept.
(520) 751-4355
FOR: Patricia Gehlen
Principal Planner
Dev Services Dept.

PROJECT:
T02CM05889
9750 E. Escalante Road
Change of use
Site Plan Review (1st review)

TRANSMITTAL: March 27, 2003


COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.


1. This project was reviewed as a change of use. Full code compliance is required. Please clarify if the proposed use is for Animal Production (Development designator "5") or commercial stables (Development designator "2"). There are different restrictions for these uses per LUC 2.2.4.2.B.1 and .B.1.a. Commercial stables in the SR zone require a 10 acre site area, see comment 4 below.
DS 2-02
2. This site is subject to Sec. 2.8.1 Hillside Development Zone (HDZ), and Sec. 2.8.6 Environmental Resource Zone (ERZ). However, the regulations of ERZ do not apply as long as there is no encroachment into the 100 year floodplain. If and when encroachment is proposed, refer to DS 2-13 and LUC 2.8.6 for ERZ submittal requirements. The HDZ Dedicated Natural Area must be delineated in a surveyable manner on the drawing. Please provide a copy of the recorded covenant running with the land, which provides protection for the natural area. Add recordation information (docket and page reference numbers) for the dedicated natural area covenant.
LUC 2.8.1
LUC 2.8.6
LUC 2.8.6.3.D
DS 2-13
LUC 2.8.1.7.B & .D
3. The site is subject to an annexation restriction, which states that no guest ranches or golf courses are permitted per C15-92-03, zoning ordinance #8033. Please add a note stating this annexation case number and detailing this restriction.
DS 3-05.2.3.C
4. Add the development designator to the project data notes. The development designator for the animal production use in the SR zone is "5". The development designator for commercial stables is "2". Also add a note detailing the restrictions which the proposed use is subject to: The animal production use in the SR zone is subject to LUC 3.5.2.1.A.1, .B.2 and .C.1. A commercial stable use is subject to 3.5.2.1.A.2 and .B.2. Please clarify per comment #1. If this is a commercial stable use, the minimum site area required is 10 acres, a requirement which this site does not meet.
DS 2-02.2.1.A.31
LUC 2.2.4.2.B.1
5. Provide a loading zone calculation which states that no loading zones are required or provided.
DS 2-02.2.1.A.14
LUC 3.4.5
6. Add vehicle and bicycle parking calcs stating that no parking is required/provided.
LUC 3.3.4
DS 2-02.2.1.A.8 & .9
7. As this is a change of use to a commercial site, paved drive is required. Please revise plan to show paved access driveway with the required minimum width dimensioned. If no paved drive area is proposed, a Board of Adjustment Variance must be approved. Place the variance case number, date of approval, what was approved and conditions of approval on the plan.
DS 2-02.2.1.A.38
8. If any signage is proposed show the location, type, size and height of the sign on the drawing. DS 2-02.2.1.A.13
9. Add future and existing site visibility triangles (SVTs) along Escalante Road at the existing access drive location. DS 2-02.2.1.A.10
DS 3-03.2.2.C
DS 3-01.5
10. Provide the dimensions and bearings of all lot lines.
DS 2-02.2.1.A.5
11. Continuous pedestrian circulation must provide connection between the buildings and the adjacent street per DS 2-08.3.1. Please revise the plan to show a sidewalk connection to Escalante Road. If no pedestrian circulation is proposed a DSMR application must be submitted and approved. Place the DSMR case number, date of approval, what was approved and conditions of approval on the plan. Or, if a Board of Adjustment Variance is sought for paving requirement (see comment 7 above), the pedestrian circulation requirement may be addressed as part of the variance application.
DS 2-02.2.1.A.12
DS 2-02.2.1.A.38
12. All lettering must be a minimum of 12 point. Revise all lettering which is not the minimum standard for microfilming/archiving.
DS 2-02.2.1.A.32
13. Please dimension the existing and future MS&R right-of-way and the distance from street monument lines to existing and future curbs and sidewalks for Escalante Rd. The right-of-way for Escalante Road is based on the MS&R plan. DS 2-02.2.1.A.19 and .21

14. Provide a floor area ratio (FAR) calculation to the plan. The FAR is calculated as the building gross floor area รท site area. The maximum allowed FAR per development designator 5 is 0.10. If designator 2 is proposed, the maximum allowed FAR is 0.06. DS 2-02.2.2.A.2


If you have any questions about this transmittal, please call Peter McLaughlin, (520) 791-5608.
04/07/2003 PETER MCLAUGHLIN HANDICAP-SITE REVIEW Approved
04/15/2003 JOE LINVILLE LANDSCAPE REVIEW Denied 1) This site is subject to the provisions of the Environmental Resource Zone, LUC 2.8.6. Submit a completed ERZ application and the necessary plans. If development will not encroach into the 100 yr. floodplain, identify the floodplain limits and identify the area as to remain natural.

2) The site is subject to the provisions of the Hillside Development Zone. Revise the HDZ plan to include grading information per DS 9-04.3.1.A and to meet the vegetation
retention requirements per DS 9-04.3.2

3) This site is subject to the Native Plant Preservation provisions of LUC 3.8. Submit a native plant preservation plan. DS 2-15.0
Revise the landscape plan to comply with DS 2-15.3.4.b.
04/15/2003 JOE LINVILLE NPPO REVIEW Denied This site is subject to the Native Plant Preservation provisions of LUC 3.8. Submit a native plant preservation plan. DS 2-15.0

Final Status

Task End Date Reviewer's Name Type of Review Description
04/29/2003 TAMI ACHONG OUT TO CUSTOMER Completed