Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T02CM05789
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/30/2003 | Robert Sherry | PLUMBING-COMMERCIAL | REVIEW | Denied | 1. Resolve the difference between drawings C-3 and P-1.2 with regard to the location of the building water supply line. 2. Provide up and downstream manhole rim elevations, and sewer inverts. Fourth request. 3. Revision 1 (10/23/03), sheet A6 redefined the walls surrounding rooms 107, 108, and 109 as 1-hour rated fire partitions. Provide protection of the fire partition penetrations in compliance with Section 607.5.3, IMC 2000. |
| 10/31/2003 | Doug Laakso | BUILDING-COMMERCIAL | REVIEW | Denied | .. DGL .. 11/5/03 .. 4TH REVIEW .. COMMENTS #S1 THROUGH #S10. PRIOR COMMENTS DATED 10/7/03. S1. DETAIL HOW FIRE-RATING IS ACCOMPLISHED AT FEC. SEE PRIOR COIMMENT #S5,S7 AND S11.11: 1. SOUTH WALL OF KITCHEN/STORAGE 2. EAST WALL OF KITCHEN/STORAGE. S2. PROVIDE DETAILS AND LISTINGS, ON DRAWINGS FOR FIRE-RATED CONSTRUCTION, PER PRIOR COMMENT #S7. S3. SEE PRIOR COMMENT #S11. 1. EXIT GATES TO MEET EXIT REQUIREMENTS, CALCULATION ON DRAWING A0, WITH OCCUPANT LOAD OF 155 ; AREA OF REFUGE MUST ACCOMMODATE ALL OCCUPANTS ~300+ , EXPLAIN/JUSTIFY. SEE PRIOR COMMENT #S11.2. 2. SEE PRIOR COMMENT #S11.4. CLARIFY HOW LANDINGS AT DOORS AND ACCESSIBILITY IS MAINTAINED AT KITCHEN/STORAGE/PLATFORM, REF. CIVIL DWGS.,A7,A0, COORDINATE FFE. 3. SEE PRIOR COMMENT #S11.5 CLEARLY SHOW HOW EXIT DISCHARGE ( IBC SEC 1006 ) IS PROVIDED, MAINTAIN EXIT WIDTH TO THE PUBLIC WAY. 4. SEE PRIOR COMMENT #S11.6. SEE COMMENT #S3.1 ABOVE. 5. SEE PRIOR COMMENT #S11.8. SEE COMMENT #S3.1 ABOVE. 6. SEE PRIOR COMMENT #S11.9. SEE ANSI A117.1-98 ed , FIG #505.10. S4. SEE PRIOR COMMENT #S12. 1. INDICATE ENTIRE ACCESSIBILE ROUTE, DUE TO MULTIPLE FFE'S, RAMPS, LANDINGS, PARKING FACILITIES, PER IBC SECTIONS #1101 THROUGH #1108. SEE PRIOR COMMENT #S12.1. 2. SEE PRIOR COMMENT #S12.2. RAMP AT EAST ACCESSIBILE PARKING SPACE IS NOT ACCEPTABLE IN ACCESS AISLE, CLARIFY GRADES, etc.,REF. DRAWING #C1, EXPLAIN NEED FOR LOCATION OF ACCESSIBILE PARKING SO FAR FROM BUILDINGS AS THESE ARE REQUIRED BY SECTION 1106.5 OF THE IBC TO BE LOCATED ON " THE SHORTEST ACCESSIBILE ROUTE OF TRAVEL FROM ADJACENT PARKING TO AN ACCESSIBILE BUILDING ENTRANCE." WHY SHOULD THESE LOCATIONS BE APPROVED AS COMPLYING WITH THE CODE? S5. SEE PRIOR COMMENT #S13. PLEASE USE CODE CALCULATED OCCUPANCY LOADS PER IBC TABLE 1003.2.2.2, ( 303 @ CLASSROOM, 2 @ KITCHEN, ~ 206 @ AMPHITHEATER ) vs 145 USED.REVISE PER IBC. S6. SEE PRIOR COMMENT #S14, #S15 AND #S16. PROVIDE RESPONSE FROM SOILS ENGINEER. CTS RESPONSE NOT ATTACHED, PLEASE PROVIDE. S7. SEE PRIOR COMMENT #S18. ADDRESS MANEUVERING CLEARANCES ( ANSI SEC 404), REACH RANGES ( ANSI SEC 308 ), ACCESS TO SINKS, KITCHENS ( ANSI SEC 804 ),SEATING AT TABLES, COUNTERS, AND WORK SURFACES ( ANSI SEC 902 ), SEE ANSI A117.1-98 ed. S8. SEE PRIOR COMMENT #S20. NO CTS LETTER ATTACHED, PLEASE PROVIDE. S9. SEE PRIOR COMMENT #S21. PROVIDE CTS LETTER/RESPONSE FOR REVIEW,NO CTS LETTER ATTACHED. S10. SEE PRIOR COMMENT #S22. NO ATTACHED CTS LETTER PLEASE PROVIDE FOR REVIEW. See prior Comments dated 10/7/03. If you should have questions on these Comments, please call Douglas Laakso, Structural Plans Examiner at (520)791-5550 x 1111. |
| 11/05/2003 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | Building plans may not be approved prior to Site Plan approval. |
| 11/13/2003 | Daniel Castro | ZONING | REVIEW | Denied | Zoning Review may not approve structural plans until the site plan is approved by all sections and the structural plans have been approved by Building Review. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/25/2003 | LISA LESNY | OUT TO CUSTOMER | Completed |
| 11/24/2003 | ANGIE SHOFFSTALL | REJECT SHELF | Completed |