Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T02CM05663
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/10/2002 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 12/11/2002 | DAVID RIVERA | NPPO | REVIEW | Passed | |
| 12/11/2002 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 12/30/2002 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM05663 12/30/02 747 N. 9TH AVE. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL PLANS SHALL BE LEGIBLE AND A SCALE NO SMALLER THAN ¼ INCH = 1-FOOT SHALL BE USED FOR ALL FLOOR PLANS, FRAMING PLANS AND ELEVATIONS. DETAILS &CROSS SECTIONS AT A MINIMUM 3/8 INCH = 1-FOOT SCALE. 2. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 3. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. STRUCTURAL PLANS: 1. SPECIFY DESIGN CRITERIA ON PLANS. VALUES FOR FLOOR DEAD LOAD AND LIVE LOAD, ROOF DEAD LOAD AND LIVE LOAD. 2. ROOF FRAMING, THE 6X8 "LEDGER" APPEARS INADEQUATE TO SPAN 18 FEET. 3. SPECIFY LUMBER GRADE AND SPECIES. 4. ROOF FRAMING, HOW ARE THE 6X6 @ COLUMNS @ THE ORIGINAL HOUSE BRACED LATERALLY? SECTIONS - DETAILS - MISC. NOTES: 1. SECTION A-A/6, SPECIFY THE ANCHOR BOLT LENGTH AND SPACEING. 2. A-A/6, BOTH TILE AND WOOD FLOORS ARE SPEC'D FOR THE LIVING AREA. PLEASE PROVIDE A DETAIL SHOWING HOW THE WOOD FLOOR IS TO BE CONNECTED TO THE CONCRETE. 6 MILL POLY? PRESSURE TREATED SLEEPERS?………? 3. A-A/6, THE MINIMUM STEM WALL THICKNESS IS 6", PLEASE SPECIFY. 4. PROVIDE A FOOTING UNDER THE6X6 COLUMNS @ THE MAIN HOUSE. 5. A-A/6, PLEASE SPECIFY A COLUMN TO CONCRETE CONNECTION. 6. PROVIDE A LINTEL SCHEDULE. 7. A-A/6, SPECIFY THE RAFTER HOLD DOWNS. 8. A-A/6, WHAT DOES THE6X8 LINTEL, ADJACENT THE 6X8 LEDGER, SUPPORT? TRIBUTARY AREA? 9. A-A/6, SPECIFY THE 2X4/2X10 RAFTER CONNECTION. 10. B-B/7PLEASE PROVIDE A CROSS SECTION OF THE HAND RAIL SHOWING THE GRIPPING GROOVE AND CONNECTION TO THE WALL. 11. B-B/7, SPECIFY THE MAXIMUM RISER HEIGHT AND THE MINIMUM TREAD WIDTH. 12. B-B/7, SPECIFY THERAFTER/BEAM CONNECTION. 13. B-B/7, SPECIFY THE 20 YEAR ROOFING MATERIAL AND THE SLOPE OF THE ROOF. PLUMBING PLANS: 1. PLEASE SUBMIT A ¼ INCH DRAWING OF THE PLUMBING. 2. THE TOTAL DEVELOPED LENGTH OF THE GAS LINE IS TO INCLUDE THE VERTICAL MEASUREMENTS. 3. SIZE THE WATER DISTRIBUTION SYSTEM. 4. GAS/9, SOME OF THE INPUT RATES ARE LESS THAN THE MINIMUM DEMANDS LISTED IN U.P.C. TABLE 12-1 5. PLBG./9, PROVIDE A VENT FOR THE SHOWER. MECHANICAL PLANS: 1. NOTE ON PLANS: MECHANICAL SHALL COMPLY WITH CHAPTERS 12 - 24 2000 IRC. 2. SIZE THE DUCT WORK. ELECTRICAL PLANS: 1. NOTE ON PLANS: ELECTRICAL WORK SHALL COMPLY WITH CHAPTERS 33 - 42, 2000 IRC. 2. ELECTRICAL LOAD CALCS./10, THE AREA OF THE PORCH AND THE ADDITION IS OVER 600 SQ.FT.. 3. ELECTRIC/10, THE EXISTING LOAD PLUS THE PROPOSED LOAD EXCEEDS THE 100 AMP SERVICE. 4. ELECTRIC/10, WHAT DOES THE "OTHER" , IN THE EXISTING LOAD CALCULATIONS REPRESENT? PROPOSED? 5. ELECTRIC/10, THE "ALT. ELEC. DRYER" DOESN'T APPEAR TO BE IN THE LOAD CALCs. 6. WHERE CEILING FANS ARE SHOWN ON THE PLANS, PROVIDE A NOTE INDICATING ONLY APPROVED OUTLET BOXES SHALL BE USED, PER E4001.6. 7. NOTE THAT LIGHT FIXTURES IN CLOTHES CLOSETS SHALL BE INSTALLED IN ACCORDANCE WITH E3903.11. 8. LIGHT FIXTURES OVER BATH TUBS ARE TO BE LISTED FOR USE IN WET AREAS. PLEASE NOTE. 9. PLEASE EQUIP THE EXISTING RESIDENCE WITH SMOKE DETECTORS. MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WITT @ 791-5550 EXT. 1110 |
| 12/31/2002 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/06/2003 | TAMI ACHONG | OUT TO CUSTOMER | Completed |