Review Details: SITE

Permit Number - T02CM05656
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/02/2003 JOE LINVILLE LANDSCAPE REVIEW Denied Revise the site and landscape plans to locate portions of the refuse storage area outside of the ten-foot wide street landscape border. LUC Table 3.7.2-I

Revise the landscape plan as necessary to eliminate conflicts with TEP easements indicated on the site plan. LUC 3.7.2.6.B
01/02/2003 JOE LINVILLE NPPO REVIEW Approved Exception, replacement plants will be used 2 30" box mesquite trees and 10 15 gal.
12/10/2002 JIM EGAN FIRE REVIEW Approved
12/20/2002 DAN CASTRO HANDICAP-SITE REVIEW Denied Refer to Zoning Review comment number 4a.
12/20/2002 DAN CASTRO ZONING REVIEW Denied COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. Lot dimensions and bearings are difficult to read. Please enlarge.
D.S. 2-02.2.1.A.5

2. Please note the proposed land use class as it is listed under L.U.C. Sec. 2.4.3. The following comments are based on Administrative and Professional Office, development designator 30. If the proposed use differs, additional comments may be forthcoming upon resubmittal of this plan.
D.S. 2-02.2.1.A.31

3. Add the maximum building height allowed for the proposed land use to general note 21.
D.S. 2-02.2.1.A.6

4. a) Handicap parking spaces must be 18 feet in length. Parking layout plan on sheet 2 of 11 indicates a length of 17.50 feet. Wheel stop curbing may be required for these spaces to prevent vehicle from hitting the handicap signs.
b) Dimension the wheel stops. Per D.S. 3-05.2.3.C.2, wheel stops must located two and one-half (2½) feet from the front of the parking space.
c) Per D.S. 3-05.2.2.D, the back-up spur must be a minimum of three (3) feet in depth and have a three (3) foot radii. Revise as required.
d) Dimension the width between the back of spur and the west lot line. Per D.S. 3-05.2.2.D, a minimum of three (3) feet must be provided between the back of spur and any wall, screen, or other obstruction over six (6) inches in height.
e) Add the following note to the parking spaces block on sheet 1 of 11: "18 parking spaces provided."
D.S. 2-02.2.1.A.8

5. a) Provide the bicycle parking calculation. Refer to L.U.C. Sec. 3.3.4 for bicycle parking requirements.
b) Provide a fully dimensioned bicycle parking space detail. Refer to D.S. 2-09 for design criteria.
D.S. 2-02.2.1.A.9/ D.S. 2-02.2.2.A.4

6. Label and dimension existing and future sight visibility triangles.
D.S. 2-02.2.1.A.10

7. If applicable, provide a detail of proposed free-standing signage, billboard, or outdoor lighting on the site plan.
D.S. 2-02.2.1.A.13/ D.S. 2-02.2.1.A.25

8. Dimension the location of the future curb.
D.S. 2-02.2.1.A.21

9. The gross floor area noted on the site map on sheet 1 of 11 differs from the square footage noted under the "parking spaces" block on the same sheet. Please revise for consistency.
D.S. 2-02.2.2.A.2

10. Per L.U.C. Sec. 3.4.5.5, one (1) 12 foot by 35 foot loading space is required. If a Board of Adjustment Variance will be applied for, please note the following: Board of Adjustment case number, date of approval, variances granted, and any conditions imposed.
D.S. 2-02.2.2.A.5

11. All requested changes must be made to the site and landscape plans.
D.S. 2-07.2.1.A
12/23/2002 JIM TATE SANITATION REVIEW Denied Written permission from the Department of Solid Waste Management must be obtained for curbside pickup.
Also see Engineering Folder comments.
12/23/2002 JIM TATE ENGINEERING REVIEW Denied The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

1. Please show estimated cut and fill quantities on the plan. A proposed fill quantity in excess of 50 yards will require a Grading Permit. If necessary, please apply for the Grading Permit with the next submittal. DS 2-02.2.1.A.17 & IBC Chapter 36 Section 6

2. No portion of the 10 ft. Landscape border can be placed in the future right-of-way (per TDOT).

3. Show proposed roof drainage. Sidewalks must be flood free for up to the 10-yr. flood event.

4. All new developments must provide centralized on-site refuse storage, collection, and pickup areas. Show refuse container location, size, and access fully dimensioned. DS 6-01.2.2.A and DS 2-02.2.1.A.32 Written permission from the Department of Solid Waste Management must be obtained for curbside pickup.
12/23/2002 JAMES TATE FLOODPLAIN REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
01/07/2003 MONICA VALDEZ OUT TO CUSTOMER Completed